Analysis of the single-phase four-quadrant PWM converter resulting in steady-state and small-signal dynamic models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 1 publication
0
11
0
Order By: Relevance
“…In view of the above problems, in order to meet the needs of distributed generation grid is proposed in this paper a multifunctional grid simulator, multi function AC grid simulator adopts advanced control strategy can not only were four quadrant operation, to achieve energy bidirectional flow, but also provide the three-phase voltage output and simulation such as voltage sag, voltage unbalance and so on various grid status and fault [6][7][8]. Calculation of the value of a given voltage under various faults by software programming to achieve grid control strategies of fundamental mode and harmonic mode, fundamental mode adopted based on the instantaneous voltage and current values of the double closed loop control system, harmonic mode the output voltage effective value feedback control, control system has a good effect, high stability, prototype experiment results show that this control scheme is feasible [9].…”
Section: Introductionmentioning
confidence: 99%
“…In view of the above problems, in order to meet the needs of distributed generation grid is proposed in this paper a multifunctional grid simulator, multi function AC grid simulator adopts advanced control strategy can not only were four quadrant operation, to achieve energy bidirectional flow, but also provide the three-phase voltage output and simulation such as voltage sag, voltage unbalance and so on various grid status and fault [6][7][8]. Calculation of the value of a given voltage under various faults by software programming to achieve grid control strategies of fundamental mode and harmonic mode, fundamental mode adopted based on the instantaneous voltage and current values of the double closed loop control system, harmonic mode the output voltage effective value feedback control, control system has a good effect, high stability, prototype experiment results show that this control scheme is feasible [9].…”
Section: Introductionmentioning
confidence: 99%
“…While in regions of relatively high grid frequency (50 or 60 Hz ac lines in most of the world), carrier ratio is greatly reduced. As a result, control structure with a fast current loop inside a slow voltage loop is not effective [3]. Instead, dc voltage and ac current are controlled together by 'phase and amplitude control', also called 'indirect current control (ICC)'.…”
Section: Introductionmentioning
confidence: 99%
“…To eliminate the time variance in the equations, instead of transforming the reference frame and applying the Park Transform, a substitution method has been adopted [8]. The first step is to rewrite the state equations including γ:…”
Section: Mathematical Model Of the 4q Convertermentioning
confidence: 99%