2015
DOI: 10.1002/jssc.201400863
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of therapeutic proteins and peptides using multiangle light scattering coupled to ultra high performance liquid chromatography

Abstract: Analysis of the physical properties of biotherapeutic proteins is crucial throughout all the stages of their lifecycle. Herein, we used size-exclusion ultra high performance liquid chromatography coupled to multiangle light scattering and refractive index detection systems to determine the molar mass, mass-average molar mass, molar-mass dispersity and hydrodynamic radius of two monoclonal antibodies (rituximab and trastuzumab), a fusion protein (etanercept), and a synthetic copolymer (glatiramer acetate) emplo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
11
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 25 publications
2
11
0
Order By: Relevance
“…In this regard, is mandatory to use suitable techniques to differentiate among closely related profiles against the distinctive heterogeneity profile of GA, without missing its minor populations 46 . We developed SE-UPLC 45 , SCX-UPLC and RP-UPLC methodologies 46 to evaluate molecular mass, electric charge and hydrophobicity distributions as the most reliable characteristics of the whole mixture of amino acid sequences and peptide lengths of GA through each stage of the manufacturing process (viz., polymerization, depolymerization, deprotection and purification) in order to assess critical process parameters and their impact on GA structural signatures.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In this regard, is mandatory to use suitable techniques to differentiate among closely related profiles against the distinctive heterogeneity profile of GA, without missing its minor populations 46 . We developed SE-UPLC 45 , SCX-UPLC and RP-UPLC methodologies 46 to evaluate molecular mass, electric charge and hydrophobicity distributions as the most reliable characteristics of the whole mixture of amino acid sequences and peptide lengths of GA through each stage of the manufacturing process (viz., polymerization, depolymerization, deprotection and purification) in order to assess critical process parameters and their impact on GA structural signatures.…”
Section: Resultsmentioning
confidence: 99%
“…All experiments were modified from the standard synthesis conditions (STD) used for GA manufacturing. GA produced by STD (GA-STD, Probioglat) has been extensively characterized in terms of its distinctive and equivalent molecular mass 45 ; electric charge and hydrophobicity 46 ; and refractive index increment and extinction coefficient 51 with respect to the reference medicinal product (Copaxone).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The advantages of using a SE-UHPLC column in place of a conventional SEC column include faster elution times, increased resolution, and smaller samples [49]. …”
Section: Applicationsmentioning
confidence: 99%