2012
DOI: 10.1002/eqe.2203
|View full text |Cite
|
Sign up to set email alerts
|

Analytical and experimental studies on midstory isolated buildings with modal coupling effect

Abstract: SUMMARY In a midstory isolated building, the isolation system is incorporated into the midstory rather than the base of the building. Because of the flexibility of the substructure below the isolation system in a midstory isolated building, the contribution of higher modes to the seismic responses of the midstory isolated structure may not be negligible, especially when the coupling of higher modes exists. To investigate this modal coupling effect, a simplified three‐lumped‐mass structural model of the midstor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 34 publications
(26 citation statements)
references
References 12 publications
0
26
0
Order By: Relevance
“…The isolation system located below the i th floor segments the N ‐story frame structure into a lower (L) portion and an isolated upper (U) portion, corresponding to N L = i − 1 and N U = N − i + 1 Degrees Of Freedom (DOF), respectively (Figure (a)). In the present paper, the two structural portions are also denominated as substructure , the former, and superstructure , the latter .…”
Section: Energy‐based Design Of Inter‐story Isolationmentioning
confidence: 99%
“…The isolation system located below the i th floor segments the N ‐story frame structure into a lower (L) portion and an isolated upper (U) portion, corresponding to N L = i − 1 and N U = N − i + 1 Degrees Of Freedom (DOF), respectively (Figure (a)). In the present paper, the two structural portions are also denominated as substructure , the former, and superstructure , the latter .…”
Section: Energy‐based Design Of Inter‐story Isolationmentioning
confidence: 99%
“…It is because that the OBMD specimen is designed based on a more comprehensive objective function, while MSI is designed only considering the seismic performance of the isolated SUP. Therefore, in the future study, the proposed optimum dynamic characteristic control approach might also be applied to the mid‐story isolation design to effectively solve its response amplification problem at the SUB . The maximum inter‐story displacement at the isolation layer of MSI under all the earthquake inputs as listed in Table is 44.7 mm.…”
Section: Comparison With Mid‐story Isolation Designmentioning
confidence: 99%
“…Therefore, in the future study, the proposed optimum dynamic characteristic control approach might also be applied to the mid-story isolation design to effectively solve its response amplification problem at the SUB. [4][5][6] The maximum inter-story displacement at the isolation layer of MSI under all the earthquake inputs as listed in Table 3 is 44.7 mm. In general, the inter-story displacement response at the CL of the OBMD specimen is much smaller than that at the isolation layer of MSI.…”
Section: Comparison With Mid-story Isolation Designmentioning
confidence: 99%
See 2 more Smart Citations