2006
DOI: 10.1002/jssc.200500174
|View full text |Cite
|
Sign up to set email alerts
|

Analytical and semipreparative resolution of ranolazine enantiomers by liquid chromatography using polysaccharide chiral stationary phases

Abstract: Novel HPLC methods were developed for the analytical and semipreparative resolution of new antianginal drug ranolazine enantiomers. Good baseline enantioseparation was achieved using cellulose tris (3,5-dimethylphenylcarbamate) (CDMPC) chiral stationary phases (CSPs) under both normal-phase and polar organic modes. The validation of the analytical methods including linearity, LODs, recovery, and precision, and the semipreparative resolution of ranolazine racemate were carried out using methanol as mobile phase… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2007
2007
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(10 citation statements)
references
References 29 publications
0
10
0
Order By: Relevance
“…The fast analysis has a total run time only 2 min per sample. This approach shows much higher throughput than previous reports [6], and is amenable for high-throughput analysis of large sample batches. The method described has been shown to be successfully applied to phase I pharmacokinetic studies in healthy subjects.…”
Section: Resultsmentioning
confidence: 88%
See 1 more Smart Citation
“…The fast analysis has a total run time only 2 min per sample. This approach shows much higher throughput than previous reports [6], and is amenable for high-throughput analysis of large sample batches. The method described has been shown to be successfully applied to phase I pharmacokinetic studies in healthy subjects.…”
Section: Resultsmentioning
confidence: 88%
“…Since ranolazine lacks strong characteristic UV absorption, a HPLC-UV detection method does not provide suitable sensitivity and selectivity for the determination of ranolazine in biological samples [6]. Herron et al [5] developed a LC-MS strategy with solid-phase extraction (SPE) procedure for estimation of ranolazine and its metabolites in human plasma, but it was not sensitive enough for pharmacokinetic studies and did not provide a detailed description of the method.…”
Section: Introductionmentioning
confidence: 99%
“…Sharma et al, [11] have developed a new isocratic validated stability indicating liquid chromatographic method using HiQ Sil C-18 HS column and mobile phase methanol: Water (99:1) with detection wave length 273 nm and the linearity was observed as 10-400 µg/mL. Luo et al, [12] have developed an analytical and semipreparative resolution of the enantiomers of Ranolazine using cellulose tris (3, 5 dimethyl phenyl carbamate chiral stationary phases. The retention times of the enantiomers were <7.5 min with flow rate 1.0 ml/min on the analytical scale with resolution greater than 2.…”
Section: Instrumentation and Chromatographic Conditionsmentioning
confidence: 99%
“…Few spectrophotometric [8], HPLC [8,9,10], LC-MS [11,17,13] and LCMS-MS [12,18] methods were reported in literature for determination of RAN. However, most of these reported in combination and most of these methods were related to the quantitative assay of RAN in human or dog plasma [7,14,15,16].…”
Section: Figure 1: Chemical Structure Of Ranolazinementioning
confidence: 99%