Analytical characteristics of a commercial ICP orthogonal acceleration time-of-flight mass spectrometer (ICP-TOFMS)

Abstract: NRC Publications Record / Notice d'Archives des publications de CNRC:http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdoc&an=8899217&lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdoc&an=8899217&lang=fr READ THESE TERMS AND CONDITIONS CAREFULLY BEFORE USING THIS WEBSITE.http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=en Vous avez des questions? Nous pouvons vous aider. Pour communiquer directement avec un auteur, consultez la première page de la revue dans laque… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
56
0

Year Published

2000
2000
2016
2016

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 67 publications
(56 citation statements)
references
References 13 publications
0
56
0
Order By: Relevance
“…155 The resolving power decreases towards low masses being, however, considerably higher than that observed for quadrupole systems. A resolution >415 at 10% peak hight for Pb and Bi (100 ng ml -1 ) using the LECO Renaissance instrument was reported.…”
Section: Icp-tof-ms Instrumentsmentioning
confidence: 88%
See 1 more Smart Citation
“…155 The resolving power decreases towards low masses being, however, considerably higher than that observed for quadrupole systems. A resolution >415 at 10% peak hight for Pb and Bi (100 ng ml -1 ) using the LECO Renaissance instrument was reported.…”
Section: Icp-tof-ms Instrumentsmentioning
confidence: 88%
“…A detailed summary of those instruments is available. 154 Analytical characteristics of an orthogonal 155 and of an-axial ICP-TOF-MS 156,157 instruments have been presented.…”
Section: Icp-tof-ms Instrumentsmentioning
confidence: 99%
“…Commercial single-reflectron ICP-TOFMS systems routinely produce mass resolution on the order of 1000-2500 for up to 1-m flight paths [36,37]. The current 35-cm geometry ICP-zoom-TOFMS system performs well within that resolution range for both operational modes.…”
Section: Zoom-tofms Mass Resolutionmentioning
confidence: 97%
“…The calculated detection limit (by Figure 3. (a) CEA-and (b) CMA-TOFMS mass spectra for lead that correspond to the data in Table 1. The baseline fluctuations in both traces are due to an impedance mismatch in the detection system that causes ringing [36,37,39]. However, when the zoom-TOFMS instrument is operated in the CMA zoom mode at a 43.5 kHz repetition rate, the LDR of the instrument is expanded.…”
Section: Dynamic Range and Detection Limitsmentioning
confidence: 99%
“…Optimization and mass calibration of the ICPoa-ToF-MS was undertaken using solution nebulization sample introduction with 200 ng/mL feed solutions of Br − or BrO 3 − as well as a mixed 10 ng/mL multielement tuning solution, as described by Sturgeon et al 28 With mass spectrometer parameters optimized, generation of volatile bromide species was undertaken using the PVG reactor, and experimental conditions yielding maximum response and stability were identified, including solution matrix composition and irradiation time (flow rate through the PVG reactor) as well as Ar gas transfer flow rate through the GLS. Once established, calibration functions were derived and limits of detection Relative response from Br − or BrO 3 − was noted for both solution nebulization and PVG sample introduction under optimum conditions of each.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%