2021
DOI: 10.1063/5.0047059
|View full text |Cite
|
Sign up to set email alerts
|

Analytical design and experiment of radial inductive displacement sensor with full-bridge structure for magnetic bearings

Abstract: In magnetic bearing systems, the air gap between the stator and the rotor is generally measured with an eddy current displacement sensor. However, the inductive displacement sensor (IDS) is a preferred choice due to its structural consistency with magnetic bearings, which contributes to a compact system design. While most of the reported IDS research studies are based on three-dimensional finite element method (3D FEM) simulation and the IDS of such studies is designed with a half-bridge structure, in this pap… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…The dual-coil series four-wire (DCSFW) excitation method is a differential bridge connection [ 27 , 28 ], where two matching resistors R m are connected in series and then in parallel with two series coils. This is a common excitation method today.…”
Section: Excitation Methods For Dual-coil Inductive Displacement Tran...mentioning
confidence: 99%
“…The dual-coil series four-wire (DCSFW) excitation method is a differential bridge connection [ 27 , 28 ], where two matching resistors R m are connected in series and then in parallel with two series coils. This is a common excitation method today.…”
Section: Excitation Methods For Dual-coil Inductive Displacement Tran...mentioning
confidence: 99%
“…The working principle of the double-coil inductive displacement transducer is shown in Figure 2 . The two coils are connected by a bridge [ 22 , 23 , 24 ], with R m as the matching resistor of the bridge circuit, U in as the excitation voltage, and Uo as the output signal. In the initial state, the sensing core is in the middle position, and the length of the sensing core inserted into the two coils is equal.…”
Section: Structure and Working Principle Of Double-coil Inductive Dis...mentioning
confidence: 99%