2018
DOI: 10.3390/su10082948
|View full text |Cite
|
Sign up to set email alerts
|

Analytical Determination of Medical Gases Consumption and Their Impact on Hospital Sustainability

Abstract: Abstract:Medical gases are known to show a great environmental impact and also to consume relevant resources in terms of hospital management. The present work reports on a study performed between 2008 and 2016 in a target set of 12 Spanish hospitals with floor area and number of beds ranging 2314-23,300 m 2 and 20-194, respectively, for which the average annual consumption rates of oxygen, nitrogen, medicinal air, carbon dioxide and nitrogen protoxide were analysed. The annual consumption of medical gases in a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(17 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…Infection risk increases with bioparticles concentration due to its increased viability as a pathogen [51]. Anesthetic gas concentration increases can be caused by a leak in equipment or due to bad practical execution, and the surgical smoke increase is derived from electrosurgery, laser, or ultrasound use [52]. The recommended minimum value of ACH is very similar in UNE 100713 and ASHRAE Standard 170, however, this parameter is not specified in EN 16244-2.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Infection risk increases with bioparticles concentration due to its increased viability as a pathogen [51]. Anesthetic gas concentration increases can be caused by a leak in equipment or due to bad practical execution, and the surgical smoke increase is derived from electrosurgery, laser, or ultrasound use [52]. The recommended minimum value of ACH is very similar in UNE 100713 and ASHRAE Standard 170, however, this parameter is not specified in EN 16244-2.…”
Section: Discussionmentioning
confidence: 99%
“…On the one hand, increasing the amount of fresh air impelled improves dilution effectiveness [53] but, on the other hand, it does not guarantee an SSI rate decrease and, nevertheless, operating costs are always raised [54]. Infection hazard is reduced by controlling air movement pattern [52,55] which leads to an equipment expenditure and operating costs reduction. OA discharge into a room through the HVAC system also contributes to lowering the concentration of medical gases and surgical smoke generated during surgery.…”
Section: Discussionmentioning
confidence: 99%
“…Hospitals commonly procure oxygen in bulk from suppliers as a compressed gas or as a cryogenic liquid, which is produced on a commercial scale through liquefaction and distillation. Oxygen is sold at a premium to the health sector, so generating it locally could save costs [49]. On-site production using compressed air with pressure swing adsorption (PSA) oxygen concentrators (OCs) has been found to reduce costs for hospitals [50].…”
Section: Oxygenmentioning
confidence: 99%
“…Using an average value from previous studies, it is assumed here that 49 percent of the total energy use is electrical demand and the remainder is thermal [24,29,69,70]. There are analytical data available for medical oxygen in hospitals [49] and the demand for this scale is assumed to be 708 kg per day.…”
Section: Specification Constraintsmentioning
confidence: 99%
“…The dust generated in these works is the main way of transmission of these fungi [6]. There is even a certain sanitary culture and sensitivity about the methodology to be used in the management of these works, mainly through the constitution of a Works Commission [7].…”
Section: Introductionmentioning
confidence: 99%