Analytical evaluation of a second generation assay for chromogranin A; a dual-site study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…Chromogranin A and NSE levels were measured on the fully automated B·R·A·H·M·S KRYPTOR ® instrument (Thermo Fisher Scientific, Hennigsdorf/Berlin, Germany) as described previously [21]. Total PSA level was measured with the B·R·A·H·M·S KRYPTOR analyser retrospectively in the DOC and the ABI/ENZA cohorts, while in the RP cohort the endpoint of PSA progression (Table S1) was assessed according to total PSA measured with the ARCHITECT analyser (Abbott Laboratories, Lake Forest, IL, USA) during clinical routine.…”
Section: Methodsmentioning
confidence: 99%
“…Chromogranin A and NSE levels were measured on the fully automated B·R·A·H·M·S KRYPTOR ® instrument (Thermo Fisher Scientific, Hennigsdorf/Berlin, Germany) as described previously [21]. Total PSA level was measured with the B·R·A·H·M·S KRYPTOR analyser retrospectively in the DOC and the ABI/ENZA cohorts, while in the RP cohort the endpoint of PSA progression (Table S1) was assessed according to total PSA measured with the ARCHITECT analyser (Abbott Laboratories, Lake Forest, IL, USA) during clinical routine.…”
Section: Methodsmentioning
confidence: 99%
“…This study provides evidence that measurement of CgA alone is sufficient in the management of patients with NETs and that routine additional measurement of CgB provides little added value. By enabling a reorganization of assay provision and set‐up within a routine service laboratory, the adoption of first‐line CgA‐only testing using a commercially available automated assay for on‐site measurement has permitted quality improvements reflected in key performance indicators, including turnaround time of test results, continued professional development for laboratory professionals, and enhancing the laboratory repertoire for specialist oncology assay service provision.…”
Section: Discussionmentioning
confidence: 99%
“…CGA levels were measured on the fully automated B.R.A.H.M.S KRYPTOR instrument (Thermo Scientific B.R.A.H.M.S GmbH, Hennigsdorf/Berlin, Germany) using the B.R.A.H.M.S. CGA II homogeneous sandwich fluoroimmuno-assay as described previously (20, 21, 22). The functional sensitivity of this assay is 13.7 ng/mL.…”
Section: Methodsmentioning
confidence: 99%