2005
DOI: 10.1117/12.597244
|View full text |Cite
|
Sign up to set email alerts
|

ANN-based calibration model of FTIR used in transformer online monitoring

Abstract: Recently, chromatography column and gas sensor have been used in online monitoring device of dissolved gases in transformer oil. But some disadvantages still exist in these devices: consumption of carrier gas, requirement of calibration, etc. Since FTIR has high accuracy, consume no carrier gas and require no calibration, the researcher studied the application of FTIR in such monitoring device. Experiments of "Flow gas method" were designed, and spectrum of mixture composed of different gases was collected wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2009
2009
2011
2011

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…Compared with Polytetrafluoroethylene membrane, Polyperfluoro ethylene-propylene membrane has higher gas permeability coefficients [15]. The transport properties of Polyperfluoro ethylene-propylene have been testified in [16]. Under that circumstance, it takes less than 96 hours for H 2 and CO to reach the equilibrium.…”
Section: Figure1 the Whole System Sketch Mapmentioning
confidence: 98%
“…Compared with Polytetrafluoroethylene membrane, Polyperfluoro ethylene-propylene membrane has higher gas permeability coefficients [15]. The transport properties of Polyperfluoro ethylene-propylene have been testified in [16]. Under that circumstance, it takes less than 96 hours for H 2 and CO to reach the equilibrium.…”
Section: Figure1 the Whole System Sketch Mapmentioning
confidence: 98%
“…Dissolved gas analysis (DGA) use different types of transformer faults correspond to different components and concentrations of dissolved gases in transformer oil to analyze the fault gases (H 2 , CO, CO 2 , CH 4 , C 2 H 6 , C 2 H 4 , and C 2 H 2 ), in order to determine the type of transformer fault. DGA can diagnose internal transformer fault regularly during the transformer operation, and will not be affected by external electromagnetic fields [4], is an effective technique which has been widely used to detect latent faults in transformer, and oil-gas permeability technology is just the important prerequisite and key technology to achieve the requirements of DGA.…”
Section: Introductionmentioning
confidence: 99%