2015
DOI: 10.1016/j.apsusc.2015.08.167
|View full text |Cite
|
Sign up to set email alerts
|

Anodic stripping voltammetry of silver(I) using unmodified GaN film and nanostructure electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 36 publications
1
5
0
Order By: Relevance
“…The common procedures for the calculation of LOD and LOQ as three and ten times the standard deviation of a blank are not well‐suited for electroanalytical techniques that exhibit a low background noise, in this case it is preferable to use the standard deviation of the intercept of the calibration curve . The LOD and LOQ achieved in our case, are highly comparable with values already reported, in the literature it has been found higher and similar limits . This allows the application of the method to samples with low concentration of ionic Ag.…”
Section: Discussionsupporting
confidence: 84%
See 1 more Smart Citation
“…The common procedures for the calculation of LOD and LOQ as three and ten times the standard deviation of a blank are not well‐suited for electroanalytical techniques that exhibit a low background noise, in this case it is preferable to use the standard deviation of the intercept of the calibration curve . The LOD and LOQ achieved in our case, are highly comparable with values already reported, in the literature it has been found higher and similar limits . This allows the application of the method to samples with low concentration of ionic Ag.…”
Section: Discussionsupporting
confidence: 84%
“…This step is essential in the silver determination because silver deposits are highly stables and in many cases two electrochemical signals are obtained, this fact hinders the exact quantification of the silver ions. Several methods have been described in which acid solutions of different electrolytes are used to improve the electro‐dissolution .…”
Section: Introductionmentioning
confidence: 99%
“…ACCEPTED MANUSCRIPT 10 The interference study was performed by adding the possible interfering common cations including Mg 2+ , Zn 2+ , Ni 2+ , Na + , Ca 2+ and K + respectively in mixture solution containing 1.0×10 -5 M Hg 2+ , Cu 2+ , Pb 2+ and Cd 2+ . The DPASV response current of Hg 2+ , Cu 2+ , Pb 2+ and Cd 2+ in the absence (I 0 ) and presence (I i ) of interfering metal ions and the relative signal changes (I i /I 0 -1) are summarized in Table 2.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…The electrochemical technique has been considered as a promising method for the detection of heavy metal ions due to its advantages of low cost, high sensitivity and good portability [9][10][11].…”
Section: Introductionmentioning
confidence: 99%
“…GaN nanostructures are excellent material for detecting Ag ? ion in electrochemical technology [4]. Photoelectrochemical water splitting (PEC-WS) performance of the dense and high-aspect-ratio GaN NWs are attributed to the enhancement of the light trapping effects that increases the driving force of the semiconductor photoelectrode for the creation of electron-hole pairs.…”
Section: Introductionmentioning
confidence: 99%