2023
DOI: 10.1021/acs.analchem.3c02371
|View full text |Cite
|
Sign up to set email alerts
|

Antibody Binding to Recombinant Adeno Associated Virus Monitored by Charge Detection Mass Spectrometry

Abstract: Recombinant adeno-associated virus (rAAV) is a leading gene therapy vector. However, neutralizing antibodies reduce its efficacy. Traditional methods used to investigate antibody binding provide limited information. Here, charge detection mass spectrometry (CD-MS) was used to investigate the binding of monoclonal antibody ADK8 to AAV serotype 8 (AAV8). CD-MS provides a label-free approach to antibody binding. Individual binding events can be monitored as each event is indicated by a shift of the antibody–antig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 29 publications
0
6
0
Order By: Relevance
“…CD-MS has been used to analyze various AAV serotypes, genome truncations, and antibody binding to AAV. 35 , 36 , 37 As shown in Figure S1 , in cceAAV2-CB-GFP vectors, the ratio of full/partial particles was enhanced by ∼14%, compared to scAAV2-CB-GFP. In the case of cceAAV8-TTR-hFIX versus scAAV8-TTR-hFIX, the ratio of full/partial particles was enhanced by 6.5%.…”
Section: Discussionmentioning
confidence: 95%
“…CD-MS has been used to analyze various AAV serotypes, genome truncations, and antibody binding to AAV. 35 , 36 , 37 As shown in Figure S1 , in cceAAV2-CB-GFP vectors, the ratio of full/partial particles was enhanced by ∼14%, compared to scAAV2-CB-GFP. In the case of cceAAV8-TTR-hFIX versus scAAV8-TTR-hFIX, the ratio of full/partial particles was enhanced by 6.5%.…”
Section: Discussionmentioning
confidence: 95%
“…AAV can elicit an immune response, and understanding antibody interactions with AAV is important. The binding of murine monoclonal antibody ADK8 to AAV8 was recently investigated using CD-MS. 67 Figure 5a shows a charge versus mass heat map measured for empty AAV8 where warmer colors indicate higher intensity. A scale is shown on the right of Figure 5a.…”
Section: ■ More Illustrative Examplesmentioning
confidence: 99%
“…30,33 Currently, nMS has been applied to measure macromolecules in the MDa mass range, such as adeno-associated virus capsids (3.5 -5 MDa), antibody-bound capsids species (5 -17 MDa), and oligomerized 20S proteasome (0.7 -9.6 MDa). [34][35][36][37] The Wysocki lab has demonstrated the application of SID, the only MS/MS that extensively dissociates MDa biomolecules, to investigate the structure of AAVs. 38 Here, we modified a commercial TIMS-Q-TOF mass spectrometer to study structures of high molecular weight (MW) protein complexes.…”
Section: Introductionmentioning
confidence: 99%