2019
DOI: 10.29122/jai.v10i2.3760
|View full text |Cite
|
Sign up to set email alerts
|

Aplikasi Teknologi Pengolahan Air Limbah Domestik Menggunakan Kombinasi Biofilter Aerobik Media Plastik Sarang Tawon Dan Biofilter Media Kerikil Dengan Aliran Ke Atas

Abstract: Air limbah domestik memberikan kontribusi besar terhadap pencemaran air di perkotaan karena penerapan pengolahannya belum optimal. Penelitian kombinasi biofilter aerobik dengan media plastik sarang tawon (MPST) dan media kerikil (MK) dilakukan untuk mengolah air limbah domestik. Pemilihan proses mempertimbangkan baku mutu dan sasaran penerapannya untuk skala individual. Kombinasi pada HRT 24 jam menurunkan COD, NH4-N, TSS masing-masing 84,09%, 81,62%, 93,9%. Pada HRT 36 jam, menurunkan COD, NH4-N, TSS masing-m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
5

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 12 publications
0
4
0
5
Order By: Relevance
“…A recommendation for further research is to conduct additional studies by introducing aeration treatment in the post-treatment of the wastewater treatment facility to assist in reducing COD and BOD levels, ensuring compliance with the established standards. According to Amri and Wesen [20], the reduction in BOD levels through aeration processes can reach 81.21% with a retention time of 72 hours. Furthermore, the reduction in COD levels through aeration processes can reach 84% with a retention time of 72 hours [21].…”
Section: Conclusion and Recommendation 41 Conclusionmentioning
confidence: 99%
“…A recommendation for further research is to conduct additional studies by introducing aeration treatment in the post-treatment of the wastewater treatment facility to assist in reducing COD and BOD levels, ensuring compliance with the established standards. According to Amri and Wesen [20], the reduction in BOD levels through aeration processes can reach 81.21% with a retention time of 72 hours. Furthermore, the reduction in COD levels through aeration processes can reach 84% with a retention time of 72 hours [21].…”
Section: Conclusion and Recommendation 41 Conclusionmentioning
confidence: 99%
“…Air limbah dalam reaktor diolah selama 5 hari. Berdasarkan penelitian (Amri and Wesen 2017), waktu tinggal hari ke-5 merupakan waktu yang paling efektif untuk menurunkan kandungan organik. Semakin lama pengolahan maka semakin besar rasio air yang digunakan terus menerus.…”
Section: Runningunclassified
“…The effluent from the aerobic tank is then flowed to the secondary sedimentation tank, so this effluent is the final result of treated water. In this study, the operation of the anaerobic-aerobic reactor is conducted for six days continuously, with the wastewater discharge adjusted to the selection observation time of 1 day (24 hours) [13]. The wastewater treatment process starts after inoculum and acclimatization from day 41 to day 47.…”
Section: Experimental Set-upmentioning
confidence: 99%