Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal–pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and renal function

Abstract: 80-kVp abdominal-pelvic CT with SAFIRE yields diagnostic image quality in oncology patients with renal dysfunction under substantially reduced iodine and radiation dose without renal safety concerns. Advances in knowledge: Using 80-kVp and SAFIRE allows for 40% iodine load and 32% radiation dose reduction for abdominal-pelvic CT without compromising image quality and renal function in oncology patients at risk of contrast-induced nephropathy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 45 publications
(82 reference statements)
0
6
0
Order By: Relevance
“…By decreasing tube voltage, a substantial reduction in CM could be achieved without negatively influencing either objective or subjective image quality. 25,26 Reducing both parameters at the same time will decrease CNR and may lead to insufficient image quality. 13 However, in the current study, CNR was comparable between groups by adapting both radiation and CM dose, as intended in the study design.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…By decreasing tube voltage, a substantial reduction in CM could be achieved without negatively influencing either objective or subjective image quality. 25,26 Reducing both parameters at the same time will decrease CNR and may lead to insufficient image quality. 13 However, in the current study, CNR was comparable between groups by adapting both radiation and CM dose, as intended in the study design.…”
Section: Discussionmentioning
confidence: 99%
“…Earlier studies focused on CM reduction in patients with reduced kidney function. By decreasing tube voltage, a substantial reduction in CM could be achieved without negatively influencing either objective or subjective image quality 25,26 . Reducing both parameters at the same time will decrease CNR and may lead to insufficient image quality 13 .…”
Section: Discussionmentioning
confidence: 99%
“…Minimizing the total volume of CM and using the least nephrotoxic CM should be applied in all cases. There have been efforts to reduce the contrast volume (iodine dose) as low as reasonably achievable during both CAG and CECT [ 50 , 105 ]. Clinicians should also consider the interval of CM administration when repeated procedures are needed because multiple doses of CM within a short period of time (24–72 h) increase the risk of CIN [ 10 , 106 ].…”
Section: Managementmentioning
confidence: 99%
“…Finally, 30 patients for halfCM protocol and 30 patients for stdCM protocol were enrolled. 20,21 As shown in Table 1, there were no significant differences in terms of age, sex, or body weight between the groups.…”
Section: Study Populationmentioning
confidence: 85%