1973
DOI: 10.1063/1.1686143
|View full text |Cite
|
Sign up to set email alerts
|

Application of Channel Multiplier Plates as Image Information Preprocessors

Abstract: The dead time of a channel plate has been regarded so far as an inevitable defect in many applications; however, it is pointed out in this paper that it can be considered as the memory time during which the input image is stored. Line drawing, moving object detection, and inversion of images were performed by an experimental preprocessor using the dead time characteristics. The device should be recognized as a two-dimensional operator with no scanning and without an electronic computer. The features of the dev… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

1976
1976
2019
2019

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…Before amplification is complete, in a given microchannel, it is unable to deliver amplification to another incoming ion. The period for a microchannel to fully recover is termed dead time, and it is typically in the millisecond range [64,72]. As most data acquisition times under MALDI-TOF MS are in the tens of microseconds, every microchannel can only receive one effective ion per acquisition event.…”
Section: (A) Electric Field and Ion Opticsmentioning
confidence: 99%
“…Before amplification is complete, in a given microchannel, it is unable to deliver amplification to another incoming ion. The period for a microchannel to fully recover is termed dead time, and it is typically in the millisecond range [64,72]. As most data acquisition times under MALDI-TOF MS are in the tens of microseconds, every microchannel can only receive one effective ion per acquisition event.…”
Section: (A) Electric Field and Ion Opticsmentioning
confidence: 99%
“…It is wellknown that the recovery times of such systems are in the order of ms and various models were developed for a better understanding and characterisation of such systems. [28][29][30][31][32] Therefore, the operation of the laser system at a pulse repetition rate of 1 kHz (corresponding to 1 ms delay between each laser shot) may lead to undesired signal loss. Note that the communication to the sub-units in the layer-by-layer approach leads to total delays of $600 ms between each red laser shot, which is sufficiently long to avoid potential gain reduction of the multichannel plate detector.…”
Section: Improvement Of Measurement Performance For Bulk Chemical Anamentioning