2003
DOI: 10.1163/156856703322601807
|View full text |Cite
|
Sign up to set email alerts
|

Application of EPR spectroscopy for elucidation of vanadium speciation in VO x /ZrO2 catalysts subject to redox treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
56
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(56 citation statements)
references
References 23 publications
0
56
0
Order By: Relevance
“…A sample of PTFE with 100% reflectance was used as reference. Electron Paramagnetic Resonance (EPR) spectra, recorded at 60 room temperature and at liquid nitrogen temperature, were run on a X-band CW-EPR Bruker EMX spectrometer equipped with a cylindrical cavity operating at 100 kHz field modulation and computer simulation of the spectra were obtained using the SIM32 programme developed by Prof. Sojka (Jagellonian University, Cracow, Poland 42 ). The XPS measurements were carried out in an ultrahigh vacuum system equipped with a VG MkII Escalab electron analyzer, working at a base pressure of 10 -10 mbar.…”
Section: Characterization Of Samplesmentioning
confidence: 99%
“…A sample of PTFE with 100% reflectance was used as reference. Electron Paramagnetic Resonance (EPR) spectra, recorded at 60 room temperature and at liquid nitrogen temperature, were run on a X-band CW-EPR Bruker EMX spectrometer equipped with a cylindrical cavity operating at 100 kHz field modulation and computer simulation of the spectra were obtained using the SIM32 programme developed by Prof. Sojka (Jagellonian University, Cracow, Poland 42 ). The XPS measurements were carried out in an ultrahigh vacuum system equipped with a VG MkII Escalab electron analyzer, working at a base pressure of 10 -10 mbar.…”
Section: Characterization Of Samplesmentioning
confidence: 99%
“…Nuclear hyperfine coupling constants (HCCs) were confirmed following computer simulation using SimEPR32 software [22]. The relative concentrations of PBN adducts (expressed in arbitrary units), as opposed to absolute concentrations according to a calibration curve, were determined by measuring the mean signal intensity of each spectral peak-to-trough line height.…”
Section: Analysesmentioning
confidence: 99%
“…Spectra simulations and fits were performed using the SIM 32 program. 47 ' RESULTS AND DISCUSSION Structural and Morphological Characterization. Figure 1 summarizes the TEM investigation performed on the anatase shape-controlled nanoparticles.…”
mentioning
confidence: 99%