1990
DOI: 10.1021/jf00100a008
|View full text |Cite
|
Sign up to set email alerts
|

Application of high-performance anion-exchange chromatography with pulsed amperometric detection to sugar analysis in citrus juices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

1992
1992
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…Total sugar content in sweet orange juices has been reported at 79.3–123.8 and 54.9–122.5 mg L −1 in sour orange juices 25. Reported results for total sugar in Hamlin and Page oranges were 94 and 105 g L −1 , respectively 26. The main portions of carbonhydrates in citrus fruits are the three simple sugars: sucrose, glucose, and fructose.…”
Section: Resultsmentioning
confidence: 99%
“…Total sugar content in sweet orange juices has been reported at 79.3–123.8 and 54.9–122.5 mg L −1 in sour orange juices 25. Reported results for total sugar in Hamlin and Page oranges were 94 and 105 g L −1 , respectively 26. The main portions of carbonhydrates in citrus fruits are the three simple sugars: sucrose, glucose, and fructose.…”
Section: Resultsmentioning
confidence: 99%
“…17 The increase in mobile phase strength (OH -) causes a decrease in analyte retention, but the higher pH increases the degree of dissociation and increases sample retention. Current was sampled during E 1 with sensitivity set at 100 µA full-scale.…”
Section: Free Sugars and Myo-inositol In Citrus Juicesmentioning
confidence: 99%
“…17 HPLC-PAD has been applied for sugars in citrus products. The electrochemical detector has high specificity and sensitivity for sugars.…”
Section: Detectionmentioning
confidence: 99%
“…In the case of organic acids, the detectors employed so far have been a UV–Vis tuned at a 210‐nm wavelength (Nour et al ., ; Kelebek & Selli, ; Scherer et al ., ); a refractive index (RI) (Amelin et al ., ); a mass spectrometer (HPLC‐MS) (Kelebek et al ., ; Flores et al ., ); or a conductivity detector (Regmi et al ., ). Compounds such as glucose, fructose and sucrose in turn have been determined through HPLC coupled to a RI detection system (Kelebek & Selli, ), an evaporative light‐scattering detector (Cheong et al ., ) or a pulsed amperometric detector (White & Widmer,).…”
Section: Introductionmentioning
confidence: 97%