2004
DOI: 10.1088/1742-6596/3/1/049
|View full text |Cite
|
Sign up to set email alerts
|

Application of polymer-gel dosimetry in stereotactic radiosurgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0

Year Published

2005
2005
2013
2013

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…The large and varied body of literature pertaining to polymer gel dosimetry applications confirms the value and versatility of the technique. In addition, the recent gel dosimetry conference, DOSGEL2004, had many contributions on the applications of polymer gel dosimetry using MRI [176][177][178][179][180][181][182][183] and OCT [134,135], including one novel application to diagnostic imaging [142]. The large number of these very recent papers highlights the increasing relevance of such work.…”
Section: Gel Applicationsmentioning
confidence: 99%
“…The large and varied body of literature pertaining to polymer gel dosimetry applications confirms the value and versatility of the technique. In addition, the recent gel dosimetry conference, DOSGEL2004, had many contributions on the applications of polymer gel dosimetry using MRI [176][177][178][179][180][181][182][183] and OCT [134,135], including one novel application to diagnostic imaging [142]. The large number of these very recent papers highlights the increasing relevance of such work.…”
Section: Gel Applicationsmentioning
confidence: 99%
“…Phantoms can easily be obtained and used as dosimeter to obtain 3-D dose distribution. Different kinds of gel dosimeters have been developed, the two main investigated groups are the aqueous gels, the Fricke gel dosimeters [4,5,6,7,8,9] and the based on radiation-induced polymerization and cross-linking of acrylic monomers, the polymer gels [3,10,11,12,13]. Imaging techniques such us spectrophotometry and MRI scanning, have been proposed [14,15,16,17].…”
Section: Introductionmentioning
confidence: 99%
“…Applied in radiation therapy, the main advantages of MRI are the high spatial resolution and the direct acquisition of multiplanar and 3-D imaging data. The Fricke gel dosimeter has been studied for determine both dose and dose distribution with accuracy and precision [12,13] ) occurs when the dosimeter is exposed the ionizing radiation [14] with the oxidation yield proportional to the absorbed dose and the absorbed dose distributions can be imaged by MRI. The studied Fricke gel solutions have been prepared using 300 Bloom gelatin [8,14,19,20] that is imported and very expensive in Brazil.…”
Section: Introductionmentioning
confidence: 99%
“…De Deene et al (2002), Salomons et al (2002), , , Lepage et al (2001aLepage et al ( , 2001b), investigating different imaging modalities for the extraction of dose information (e.g. Mather and Baldock (2003), Oldham et al (2001), Hilts et al (2000)) and applications of polymer gel dosimetry to the verification of complex dose distributions (Novotny et al 2004, Gustavsson et al 2003, De Deene 2002. X-ray computed tomography (CT) imaging has been shown to be a promising imaging modality for dose information extraction (Hilts et al 2000, 2005, Trapp et al 2001 due to its ease of operation, robustness and availability in the radiation clinic.…”
Section: Introductionmentioning
confidence: 99%