2008
DOI: 10.1016/j.sna.2008.01.024
|View full text |Cite
|
Sign up to set email alerts
|

Application of vertical microreactor stack with polystylene microbeads to immunoassay

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 21 publications
0
11
0
Order By: Relevance
“…The formula (Eq.1) which is newly defined from the principle based on the governing equation (Ukita et al 2008) in complex microchannel network is used to estimate the concentrations of the solution for six reaction chambers. The experimental results are compared with the theoretical value of C (i, N) estimated by the Eq.…”
Section: Characterization Of the Integrated Microfluidic Devicementioning
confidence: 99%
See 1 more Smart Citation
“…The formula (Eq.1) which is newly defined from the principle based on the governing equation (Ukita et al 2008) in complex microchannel network is used to estimate the concentrations of the solution for six reaction chambers. The experimental results are compared with the theoretical value of C (i, N) estimated by the Eq.…”
Section: Characterization Of the Integrated Microfluidic Devicementioning
confidence: 99%
“…Each enzyme in the conjugates is able to covert hundreds of substrates into products, therefore amplifies the detectable signal and enhances the sensitivity of the assay. Several ELISA microchips are developed based on an immunoreaction on the surface of a single microchannel (Mao et al 2002) or on microbeads that are trapped in the microchannel (Ukita et al 2008). James Lee and co-workers (Lai et al 2004) present an integrated microfluidic device on a compact disk (CD) to perform ELISA for rat IgG from hybridoma cell culture, the microfluidic platform combines several microfluidic functions and each step of the ELISA process is carried out automatically by controlling the rotation speed of the CD.…”
Section: Introductionmentioning
confidence: 99%
“…Chemical reaction takes place on the surface of the catalyst and hence, reaction rate is influenced by the amount of catalyst rather than the volume of reactor. (Ukita et al 2008) fabricated a vertically stacked 3D reactor structure to conduct competition enzyme-linked immunosorvent assay (ELISA). Analyte nonylphenol (NP) and enzyme-labeled alkylphenol (AP) and antibody immobilized polystyrene microbeads were mixed off-chip.…”
Section: Liquid Phase Reactormentioning
confidence: 99%
“…Microfluidic mixing is a critical operation in many chemical and biological applications 7 such as chemical synthesis, [8][9][10][11][12][13] polymerization, [14][15][16] extraction, [17][18][19][20][21] DNA analysis, [22][23][24][25][26] enzyme assays, 25,[27][28][29] and protein folding. [30][31][32][33] However, mixing is a challenge at the low Reynolds numbers typical of microfluidic device operation since the fluid flow is laminar.…”
Section: Introductionmentioning
confidence: 99%