Application of Zeeman background correction to direct current plasma excited atomic absorption spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2002
2002
2011
2011

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…We have earlier observed that S rel is systematically lower in the presented atomizer than for ame and furnace atomizers. 13 On the other hand, the theoretically calculated S rel was also probably too high because in the calculations the in uence of nuclear spin has not been taken into account. For instance, Fernandez et al 14 reported on the experiments in a furnace atomizer, in which they found that S rel 5 0.41 in a magnetic eld of 0.3 and 0.9 T. The experimental effective absorption cross section was also lower than predicted.…”
Section: Discussionmentioning
confidence: 97%
“…We have earlier observed that S rel is systematically lower in the presented atomizer than for ame and furnace atomizers. 13 On the other hand, the theoretically calculated S rel was also probably too high because in the calculations the in uence of nuclear spin has not been taken into account. For instance, Fernandez et al 14 reported on the experiments in a furnace atomizer, in which they found that S rel 5 0.41 in a magnetic eld of 0.3 and 0.9 T. The experimental effective absorption cross section was also lower than predicted.…”
Section: Discussionmentioning
confidence: 97%
“…In this case, a mixture of wood (spruce heartwood or bark) and waste was co-combusted [381]. Cadmium and lead were measured by AAS using Zeeman background correction [385] At the cyclone outlet, measured flue gas concentrations were in the range 0.04e0.74 mg/m 3 for cadmium and <0.6e4 mg/m 3 for lead. In the freeboard, concentrations determined for Cd were 0.042e0.54 mg/ m 3 and for Pb were <0.6e5.9 mg/m 3 .…”
Section: Dc-plasmamentioning
confidence: 99%
“…In this case, detection of metal species was by AAS only, making use of the Zeeman background correction [223,385] method using magnetic fields of up to 0.88 T to remove background interferences.…”
Section: Dc-plasma Spectroscopymentioning
confidence: 99%
“…12 Since then, a modi cation of the method dedicated to the measurem ent of heavy metals was developed, 13 which is based on a hollow cathode lamp and Zeeman background correction. 14 In the case of the alkali metals, the measurement is based on the use of a broadband light source, which allows a m ore rugged and simple construction, also capable of operation at elevated pressures. Compared with the earlier work, laboratory tests using a calibration unit have indicated that in the case of alkali m etals, the assum ption of chemical equilibrium m ay lead to erroneous results.…”
mentioning