2022
DOI: 10.3390/s22197240
|View full text |Cite
|
Sign up to set email alerts
|

Armband Sensors Location Assessment for Left Arm-ECG Bipolar Leads Waveform Components Discovery Tendencies around the MUAC Line

Abstract: Sudden cardiac death (SCD) risk can be reduced by early detection of short-lived and transient cardiac arrhythmias using long-term electrocardiographic (ECG) monitoring. Early detection of ventricular arrhythmias can reduce the risk of SCD by allowing appropriate interventions. Long-term continuous ECG monitoring, using a non-invasive armband-based wearable device is an appealing solution for detecting early heart rhythm abnormalities. However, there is a paucity of understanding on the number and best bipolar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 29 publications
(77 reference statements)
0
7
0
Order By: Relevance
“…Beat-by-beat (BbyB) segmentation of each subject case for the simultaneous ICG and ECG recordings (for both arm and thorax ICG modes) was based on the single fiducial point (SFP) technique previously reported [7,23,24], which was applied to the ECG signal recorded in a particular ICG mode and subject case as the reference signal for extracting the accurate time position of valid ventricular depolarisation events of QRS complexes along the whole ECG recording. Therefore, the output from the SFP process is a vector of sample numbers (n) of valid heartbeat QRS complexes at the SFP position along the 480 s simultaneous ICG and ECG recording length.…”
Section: Beat-by-beat Recursive Ensemble Averaging Denoising Process ...mentioning
confidence: 99%
See 4 more Smart Citations
“…Beat-by-beat (BbyB) segmentation of each subject case for the simultaneous ICG and ECG recordings (for both arm and thorax ICG modes) was based on the single fiducial point (SFP) technique previously reported [7,23,24], which was applied to the ECG signal recorded in a particular ICG mode and subject case as the reference signal for extracting the accurate time position of valid ventricular depolarisation events of QRS complexes along the whole ECG recording. Therefore, the output from the SFP process is a vector of sample numbers (n) of valid heartbeat QRS complexes at the SFP position along the 480 s simultaneous ICG and ECG recording length.…”
Section: Beat-by-beat Recursive Ensemble Averaging Denoising Process ...mentioning
confidence: 99%
“…Therefore, the output from the SFP process is a vector of sample numbers (n) of valid heartbeat QRS complexes at the SFP position along the 480 s simultaneous ICG and ECG recording length. Thus, the heartbeat sample positions SFP vector was used for the accurate segmentation of both the simultaneous ICG and the ECG signals by defining 1400 samples (700 ms) centred around each sample point (element) in the SFP vector [23].…”
Section: Beat-by-beat Recursive Ensemble Averaging Denoising Process ...mentioning
confidence: 99%
See 3 more Smart Citations