Arterial pulsatility improvement in a feedback-controlled continuous flow left ventricular assist device: An ex-vivo experimental study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
19
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 26 publications
(20 citation statements)
references
References 37 publications
1
19
0
Order By: Relevance
“…The balloon pump is placed in the left ventricle, at the same time, the control and drive units are placed in vitro. The inflated volume of the balloon used in this study is 50 cm 3 , and has a smaller implanted volume about 7 cm 3 when it is deflation (likes long cylinder, diameter 1 cm and length 5.6 cm), and thus creates a smaller operation wound. During the systole, the balloon is inflating and pushing the blood into aorta, and meanwhile increasing pressure of the left ventricle.…”
Section: Materials and Methods Ivadmentioning
confidence: 99%
See 2 more Smart Citations
“…The balloon pump is placed in the left ventricle, at the same time, the control and drive units are placed in vitro. The inflated volume of the balloon used in this study is 50 cm 3 , and has a smaller implanted volume about 7 cm 3 when it is deflation (likes long cylinder, diameter 1 cm and length 5.6 cm), and thus creates a smaller operation wound. During the systole, the balloon is inflating and pushing the blood into aorta, and meanwhile increasing pressure of the left ventricle.…”
Section: Materials and Methods Ivadmentioning
confidence: 99%
“…These cavities were placed in acrylic chambers. The ventricular sac is a semi-ellipsoid (long axis -180 mm and short axis À 62 mm) and its volume is approximately 181 cm 3 . Ventricular diastole and systole were controlled by two electropneumatic regulators (ITV2030-312BL, SMC Pneumatics, Tokyo, Japan) and two vacuum proportional valves (ITV2090-31N2BN5) and 3/2 way solenoid valves (VT325-025GS, SMC Pneumatics, Tokyo, Japan).…”
Section: Mock Circulatory Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The present study aims to operate a CF-LVAD in co-pulsation support mode, similar to previous studies [ 31 , 32 ], and assess whether the co-pulsation support mode significantly increases arterial pulsatility in a mock circulatory system. Furthermore, a complete control method is presented and applied experimentally by using a physiological model to describe the reference pump flow.…”
Section: Introductionmentioning
confidence: 99%
“…Several studies have modulated CF-VAD speeds to examine the effects on aortic pulsatility. Bozkurt et al utilized a mock circulatory loop with an ex-vivo porcine heart controlled by a pacemaker to test their novel proportional-integral (PI) controller for device outflow in a MicroMed DeBakey VAD (Bozkurt et al, 2014). The PI controller set the pump flow rate, the control variable, during the first 1/4 th of the cardiac cycle.…”
Section: B Pulsatilitymentioning
confidence: 99%