Assessing the Accuracy of Continuous Glucose Monitoring (CGM) Calibrated With Capillary Values Using Capillary or Venous Glucose Levels as a Reference

Abstract: Background: Using the standard venous reference for the evaluation of continuous glucose monitoring (CGM) systems could possibly negatively affect measured CGM accuracy since CGM are generally calibrated with capillary glucose and venous and capillary glucose concentrations differ. We therefore aimed to quantify the effect of using capillary versus venous glucose reference samples on estimated accuracy in capillary calibrated CGM. Methods:We evaluated 41 individuals with type 1 diabetes mellitus (T1DM) using t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
23
0
1

Year Published

2016
2016
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(26 citation statements)
references
References 30 publications
2
23
0
1
Order By: Relevance
“…The accuracy of CGM and FGM sensors have been studied against frequently sampled venous and capillary blood. [ 12 15 16 ] In this study, the linear regression coefficient of AGP over RBS was 0.93 and that of AGP over CBG was 0.89 which is comparable to a recently published study evaluating the performance and usability of “FGM system” involving adults. [ 12 ] In our study, MARD for AGP over RBS was 9.56% and that of AGP over CBG was 15.07%.…”
Section: Discussionsupporting
confidence: 85%
See 1 more Smart Citation
“…The accuracy of CGM and FGM sensors have been studied against frequently sampled venous and capillary blood. [ 12 15 16 ] In this study, the linear regression coefficient of AGP over RBS was 0.93 and that of AGP over CBG was 0.89 which is comparable to a recently published study evaluating the performance and usability of “FGM system” involving adults. [ 12 ] In our study, MARD for AGP over RBS was 9.56% and that of AGP over CBG was 15.07%.…”
Section: Discussionsupporting
confidence: 85%
“…[ 16 ] Other studies comparing various CGM devices have quoted similar numbers. [ 15 16 ] In this study, MARD was lower when AGP was compared to RBS than when it was compared to CBG.…”
Section: Discussionmentioning
confidence: 60%
“…This would mean that the ISF glucose values are not of lower relevance than the BG values, but rather just the opposite. This, in turn, also means that the improvements observed over the last decade with the parameter used most often to characterize the analytical performance of CGM systems, 11,12 the mean (or median) absolute relative difference (MARD), will never be as low as when two BG measurement systems (system refers to the combination of the meter and the test strips) are compared. The MARD will reach a certain limit due to basic differences between the two measurement approaches (see above).…”
Section: Are the Differences Between Blood And Isf Glucose Levels Simmentioning
confidence: 99%
“…However, CGM is expensive and not widely available due to limited reimbursement [18]. Moreover, CGM accuracy also remains a challenge; most of the available systems require calibration with capillary BG at least twice daily to allow a sufficiently reliable correlation between interstitial and capillary glucose results [19]. …”
Section: Introductionmentioning
confidence: 99%