2007
DOI: 10.1109/tuffc.2007.426
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of Anisotropic Tissue Elasticity of Cortical Bone from High-Resolution, Angular Acoustic Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
35
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(36 citation statements)
references
References 34 publications
1
35
0
Order By: Relevance
“…Quantitative scanning acoustic microscope (SAM) data of a human femur from another study were used for this investigation (Lakshmanan et al 2007). A disk was extracted from the proximal diaphysis approximately 21% below the proximal end of the femur.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Quantitative scanning acoustic microscope (SAM) data of a human femur from another study were used for this investigation (Lakshmanan et al 2007). A disk was extracted from the proximal diaphysis approximately 21% below the proximal end of the femur.…”
Section: Methodsmentioning
confidence: 99%
“…It was chosen such that the homogeneity of the microstructure was maximum to the authors' eyes, that is, areas including very large pores or an obvious porosity gradient were avoided. The pixels in pores were segmented from the pixels in the bone matrix using a fixed impedance threshold determined empirically (Lakshmanan et al 2007). The porosity p was calculated as the area of pores in the plane (x, y) divided by total area.…”
Section: Methodsmentioning
confidence: 99%
“…The relation between stiffness and acoustic impedance tensor for anisotropic materials has been derived by Lakhsmanan et al [53]. The apparent properties, i.e.…”
Section: Scanning Acoustic Microscopy (Sam)mentioning
confidence: 99%
“…The principles of the acoustic data acquisition and the conversion of the measured reflection amplitude to acoustic impedance and elastic coefficients have been described elsewhere (Lakshmanan et al, 2007;Raum et al, 2003Raum et al, , 2004Raum, 2008) and are summarized in the appendix.…”
Section: Theoretical Background Of Parameter Extractionmentioning
confidence: 99%
“…Calibrated scans of the confocal reflection amplitude of the flat and cylindrically shaped samples were performed, as described in Lakshmanan et al (2007), Raum (2008). For the cylinder scans, a rotational stage (DT-80; Micos GmbH, Eschbach, Germany) and a custom made sample holder were attached to the microscope.…”
Section: Scanning Acoustic Microscopymentioning
confidence: 99%