2021
DOI: 10.1016/j.jobe.2021.102824
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of construction workers’ perceived risk using physiological data from wearable sensors: A machine learning approach

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
36
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 50 publications
(36 citation statements)
references
References 115 publications
0
36
0
Order By: Relevance
“…In addition, only three investigations [40][41][42] declared randomisation procedures in the participants category, and none described power adjustment or consideration to account for the adequacy of sample size. For four cases [48,53,65,76], with samples under 10 participants, the number of subjects was not considered representative to assure statistical power in the study. As part of the data sources evaluation, nearly half of the papers [42][43][44][45][46]48,49,51,52,54,56,58,60,63,72,73,77]) indicated that not all subjects homogeneously completed all parts of the protocols.…”
Section: Risk Of Bias Assessment and Quality Of Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…In addition, only three investigations [40][41][42] declared randomisation procedures in the participants category, and none described power adjustment or consideration to account for the adequacy of sample size. For four cases [48,53,65,76], with samples under 10 participants, the number of subjects was not considered representative to assure statistical power in the study. As part of the data sources evaluation, nearly half of the papers [42][43][44][45][46]48,49,51,52,54,56,58,60,63,72,73,77]) indicated that not all subjects homogeneously completed all parts of the protocols.…”
Section: Risk Of Bias Assessment and Quality Of Resultsmentioning
confidence: 99%
“…These devices included the Equivital LifeMonitor [21] (a multivariable signal device with ECG and respiratory monitor, inbuilt medical-grade thermometer and tri-axis accelerometer), identified in seven studies [42,51,57,63,69,73,77], and the Zephyr status monitor (including ECG, skin temperature, breathing rate and tri-axis inertial signals) observed in three [45,53,56]. Wristband-type devices such as the E4 from Empatica (including PPG, electrodermal activity, skin temperature and tri-axis signals) and the Basis Fitness (PPG and tri-axial signals) were also used in two studies each [49,50,59,76].…”
Section: Physiological Monitoring Systems and Processing Methodsmentioning
confidence: 99%
See 3 more Smart Citations