2011
DOI: 10.1152/ajpheart.00708.2010
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of endothelial function of large, medium, and small vessels: a unified myograph

Abstract: Lu X, Kassab GS. Assessment of endothelial function of large, medium, and small vessels: a unified myograph. Am J Physiol Heart Circ Physiol 300: H94 -H100, 2011. First published November 12, 2010; doi:10.1152/ajpheart.00708.2010.-Endothelial dysfunction precedes the development of morphological atherosclerotic changes and can also contribute to lesion development in cardiovascular diseases. Currently, there is a lack of a single method to determine endothelial function of the entire range of vessel dimension… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
31
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
4

Relationship

3
7

Authors

Journals

citations
Cited by 30 publications
(32 citation statements)
references
References 27 publications
(28 reference statements)
1
31
0
Order By: Relevance
“…The heart was harvested and placed in an ice-cold saline bath. A fresh right coronary artery (RCA) of ϳ2.5 cm was dissected free of fat and connective tissue, and the branches were ligated with suture under dissection microscope in 4°C HEPES PSS (physiological saline solution) (16,17).…”
Section: Methodsmentioning
confidence: 99%
“…The heart was harvested and placed in an ice-cold saline bath. A fresh right coronary artery (RCA) of ϳ2.5 cm was dissected free of fat and connective tissue, and the branches were ligated with suture under dissection microscope in 4°C HEPES PSS (physiological saline solution) (16,17).…”
Section: Methodsmentioning
confidence: 99%
“…28,29 Although endothelial dysfunction may be indicated by several biomarkers, the vasodilation of blood vessel in response to endothelium-dependent agonists is the gold standard. 30 For in vitro studies, the wire and pressure myographs have been used extensively to study the vasoreactivity and pharmacology of the large and small vessels, respectively. [31][32][33] The wire myograph is used in studies with vessels a diameter range from large vessels (aorta) down to about 500 μm.…”
Section: Functional In Vitro Assessment Of CCmentioning
confidence: 99%
“…A pressure transducer (SPR-524, Microtip catheter transducer, Millar) was used to monitor the intraluminal pressure, and a volume compensator was used to compensate for water transport across the vessel wall. The vascular contraction during endothelin 1 stimulation was measured as changes in intraluminal pressure (36).…”
Section: Generation Of Targeting Vector For Homologous Recombination-mentioning
confidence: 99%