2018
DOI: 10.1016/j.dib.2017.11.003
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of groundwater quality and evaluation of scaling and corrosiveness potential of drinking water samples in villages of Chabahr city, Sistan and Baluchistan province in Iran

Abstract: The aims of this study were to assess and analysis of drinking water quality of Chabahar villages in Sistan and Baluchistan province by water quality index (WQI) and to investigate the water stability in subjected area. The results illustrated that the average values of LSI, RSI, PSI, LS, and AI was 0.5 (±0.34), 6.76 (±0.6), 6.50 (±0.99), 2.71 (±1.59), and 12.63 (±0.34), respectively. The calculation of WQI for groundwater samples indicated that 25% of the samples could be considered as excellent water, 50% of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
59
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 95 publications
(60 citation statements)
references
References 8 publications
1
59
0
Order By: Relevance
“…According to Table 4, the mean pH in the study areas was 8.3, which is reasonable according to national standards for permitted levels and pleasant levels (6.5 -9). Water TDS was at appropriate levels with the exception of water in Blueredy and Elyasvand which were over the standard levels (16)(17)(18).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…According to Table 4, the mean pH in the study areas was 8.3, which is reasonable according to national standards for permitted levels and pleasant levels (6.5 -9). Water TDS was at appropriate levels with the exception of water in Blueredy and Elyasvand which were over the standard levels (16)(17)(18).…”
Section: Discussionmentioning
confidence: 99%
“…The accuracy of indices was estimated according to their capacity in determining states such as under-saturated, saturated, and over-saturated calcium carbonate. These included the LSI, RSI, PSI, and AI indices which were calculated according to the aforementioned parameters in Table 3 (17).…”
Section: Calculating Measuring Indicesmentioning
confidence: 99%
“…1 ) and its aquifers are located in South-East Iran between the latitudes 29° 30′ 45′′ N and longitudes 60° 51′ 25′′ E [1] , [2] . The subjected study area is a semi-flat plain region with a gentle slope toward the south has a warm, temperate climate with an annual average of 18.3 °C in which the highest and lowest temperatures are 42.5 °C and −12.6 °C, respectively [3] , [4] .
Fig.
…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%
“…Seventy one samples of different brands of bottled waters were chosen randomly, and then the fluoride concentration of water samples was determined by Ion Chromatography No. 4110 based on the method mentioned in the book of standard methods for water and wastewater experiments [8] , [9] , [10] , [11] , [12] , [13] , [14] , [15] , [16] , [17] , [18] , [19] , [20] , [21] , [22] , [23] , [24] , [25] , [26] , [27] , [28] , [29] .…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%