2020
DOI: 10.1016/j.ygyno.2020.09.025
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of protein biomarkers for preoperative differential diagnosis between benign and malignant ovarian tumors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(15 citation statements)
references
References 33 publications
1
14
0
Order By: Relevance
“…Proteins were measured with a Luminex assay, according to the manufacturers’ instructions and as described earlier by our group [ 12 ]. The following immune-related proteins were analysed: interleukin-10 (IL-10), IL-12, IL-17 arginase, eotaxin-1/C-C motif chemokine ligand 11 (CCL11), eotaxin-2/C-C motif chemokine ligand 24 (CCL24), transforming growth factor β/latency-associated peptide (TGF-β/LAP), galectin-3, matrix metallopeptidase-1 (MMP-1), MMP-7, MMP-8, MMP-9, MMP-12, MMP-13, interferon gamma-induced protein 10/C-X-C motif chemokine ligand 10 (IP-10/CXCL10), macrophage-derived chemokine/C-C motif chemokine ligand 22 (MDC/CCL22), monokine induced by gamma interferon/C-X-C motif chemokine ligand 9 (MIG/CXCL9), osteopontin (OPN), vascular endothelial growth factor (VEGF), RANTES/C-C motif chemokine ligand 5 (CCL5), serum amyloid A (SAA), stromal cell-derived factor 1 alpha/C-X-C motif chemokine ligand 12 (SDF-1alpha/CXCL12).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…Proteins were measured with a Luminex assay, according to the manufacturers’ instructions and as described earlier by our group [ 12 ]. The following immune-related proteins were analysed: interleukin-10 (IL-10), IL-12, IL-17 arginase, eotaxin-1/C-C motif chemokine ligand 11 (CCL11), eotaxin-2/C-C motif chemokine ligand 24 (CCL24), transforming growth factor β/latency-associated peptide (TGF-β/LAP), galectin-3, matrix metallopeptidase-1 (MMP-1), MMP-7, MMP-8, MMP-9, MMP-12, MMP-13, interferon gamma-induced protein 10/C-X-C motif chemokine ligand 10 (IP-10/CXCL10), macrophage-derived chemokine/C-C motif chemokine ligand 22 (MDC/CCL22), monokine induced by gamma interferon/C-X-C motif chemokine ligand 9 (MIG/CXCL9), osteopontin (OPN), vascular endothelial growth factor (VEGF), RANTES/C-C motif chemokine ligand 5 (CCL5), serum amyloid A (SAA), stromal cell-derived factor 1 alpha/C-X-C motif chemokine ligand 12 (SDF-1alpha/CXCL12).…”
Section: Methodsmentioning
confidence: 99%
“…Proteins were measured with a Luminex assay, according to the manufacturers' instructions and as described earlier by our group [12]…”
Section: Protein Analysismentioning
confidence: 99%
See 2 more Smart Citations
“…Human epididymal protein (HE4) can detect a small fraction of OC patients missed by CA125 [ 3 ]. The study showed that the diagnostic value of CA125 and HE4 with areas under the receiver operating characteristic curves (AUCs) were 0.78 and 0.76, respectively, for the discrimination between benign and stage I OC [ 6 ]. However, these serum markers are not ideal biomarkers in the early detection of OC due to their limited sensitivity [ 7 ].…”
Section: Introductionmentioning
confidence: 99%