2013
DOI: 10.3390/en6105069
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of the Economic and Environmental Impact of Double Glazed Façade Ventilation Systems in Mediterranean Climates

Abstract: Free convection is the most often used method in order to reduce solar load gains on a building with double glazed façades (DGFs). However, depending on the climate factors, the thermal performance of a DGF may not be satisfactory and extra energy costs are required to obtain suitable comfort conditions inside the building. Forced ventilation systems are a feasible alternative to improve the thermal performance of a DGF in Mediterranean climates where large solar gains are a permanent condition throughout the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 17 publications
0
7
0
Order By: Relevance
“…The standard k-epsilon (k-e) turbulence model which is frequently used for incompressible flows, was used to define the turbulence kinetic energy and flow dissipation rate within the model [29]. The use of the standard k-e transport model on building configurations has been found accurate in previous works on natural ventilation studies [2][3][4][5][30][31][32][33][34]. The governing equations for the mass conservation, momentum conservation, energy conservation, turbulence kinetic energy and dissipation rate are not included here but fully available in the FLUENT user guide [35].…”
Section: Computational Modellingmentioning
confidence: 99%
“…The standard k-epsilon (k-e) turbulence model which is frequently used for incompressible flows, was used to define the turbulence kinetic energy and flow dissipation rate within the model [29]. The use of the standard k-e transport model on building configurations has been found accurate in previous works on natural ventilation studies [2][3][4][5][30][31][32][33][34]. The governing equations for the mass conservation, momentum conservation, energy conservation, turbulence kinetic energy and dissipation rate are not included here but fully available in the FLUENT user guide [35].…”
Section: Computational Modellingmentioning
confidence: 99%
“…[32][33][34][35][36][37][38][39][40]. As the first round is a brainstorming round, the questionnaire was designed to give the respondents (experts) the opportunity to add more techniques and strategies for Saudi Arabian context not already covered by the questionnaire.…”
Section: Data Collection-delphi Questionnaire Descriptionmentioning
confidence: 99%
“…The effect of cooling by blowing air through the channel (between the inner and outer glasses) was analyzed by Perez-Grande et al [7]. Valetin et al [9] conducted an economic assessment of a fan and nozzle-ventilated system for forced ventilation in the air gap for a double skin façade.…”
Section: Façade Types and Characteristicsmentioning
confidence: 99%