2016
DOI: 10.1016/j.procir.2016.02.018
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of the Measurement Procedure for Dimensional Metrology with X-ray Computed Tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(15 citation statements)
references
References 4 publications
0
15
0
Order By: Relevance
“…Significant research has been performed in relation to dimensional metrology using XCT. This dimensional research includes measurement accuracy [2,3], scaling error compensation [4] and development of XCT measurement procedures and workflows [5,6]. Surface texturefrom-XCT extraction and characterisation, however, is in its infancy, but If XCT is to be used as an industrial inspection tool for component surface texture acceptance then this measurement and characterisation will need to be performed per accepted reference standards, such as ISO 25178.…”
Section: Introductionmentioning
confidence: 99%
“…Significant research has been performed in relation to dimensional metrology using XCT. This dimensional research includes measurement accuracy [2,3], scaling error compensation [4] and development of XCT measurement procedures and workflows [5,6]. Surface texturefrom-XCT extraction and characterisation, however, is in its infancy, but If XCT is to be used as an industrial inspection tool for component surface texture acceptance then this measurement and characterisation will need to be performed per accepted reference standards, such as ISO 25178.…”
Section: Introductionmentioning
confidence: 99%
“…The reference value for each material is usually calculated as the peak value assigned to that material in the histogram graph ( Figure 4). Although this method is widely used in multiple applications due to its simplicity, it does not guarantee an accurate determination of the surface [22,28]. Therefore, in this work, the threshold value obtained by the ISO50 method has been corrected.…”
Section: Local Threshold Methods (Ct1)mentioning
confidence: 99%
“…Different measuring strategies are also compared in [25], where three different inspection software packages for volume and surface data analysis were applied. Additionally, the authors in [26] evaluated and quantified the repeatability of post-processing settings, such as data fitting, the definition of the datum system and surface determination, which is also analyzed in [27,28]. As some of these works show, the surface extraction technique used is one of the most influent factors in the final measurement uncertainty.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the investigation of permeability was performed by measurement of remaining air inside the specimen. Pores filled with air were segmented by an ISO50 threshold between the air and bone foam material peak in the grey value histogram [10]. Eventually detected bubbles of air outside of the bone foam material were removed manually from the data.…”
Section: Image Processingmentioning
confidence: 99%