2018
DOI: 10.1002/jbio.201700139
|View full text |Cite
|
Sign up to set email alerts
|

Assessment of tissue polarimetric properties using Stokes polarimetric imaging with circularly polarized illumination

Abstract: Tissue-depolarization and linear-retardance are the main polarization characteristics of interest for bulk tissue characterization, and are normally interpreted from Mueller polarimetry. Stokes polarimetry can be conducted using simpler instrumentation and in a shorter time. Here, we use Stokes polarimetric imaging with circularly polarized illumination to assess the circular-depolarization and linear-retardance properties of tissue. Results obtained were compared with Mueller polarimetry in transmission and r… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
22
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 18 publications
(25 citation statements)
references
References 58 publications
3
22
0
Order By: Relevance
“…3(a) ) is slightly more prominent than that in backscattering image (1.5%, Fig. 3(b) ), which was also observed in our recent study [ 39 ]. However both in forward and backward measurements, the differences of parameter Δ between connective tissues and hepatic lobules are slight, indicating that the depolarization abilities of the connective tissues and hepatic lobules in this porcine liver sample are close.…”
Section: Resultssupporting
confidence: 88%
See 3 more Smart Citations
“…3(a) ) is slightly more prominent than that in backscattering image (1.5%, Fig. 3(b) ), which was also observed in our recent study [ 39 ]. However both in forward and backward measurements, the differences of parameter Δ between connective tissues and hepatic lobules are slight, indicating that the depolarization abilities of the connective tissues and hepatic lobules in this porcine liver sample are close.…”
Section: Resultssupporting
confidence: 88%
“…In this coordinate system there is an opposite sign of Mueller matrix element m24 or m42 on Figs. 2(a) and 2(b) [ 39 ]. The sign convention does not change the values of MMT and MMPD parameters.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“… a Stokes vector based approaches: (i) DOP, DOLP and DOCP 2 – 5 ; (ii) Stokes vector projection approach 158 ; (iii) Stokes vector location approach 159 ; (iv) Dipole orientation differentiation approach. Polarisation angle (PA) and intensity are used as main parameters 154 , 155 .…”
Section: Vectorial Information Extraction Methods For Biomedical Applicationsmentioning
confidence: 99%