2020
DOI: 10.11591/ijpeds.v11.i2.pp605-610
|View full text |Cite
|
Sign up to set email alerts
|

Asymmetric hybrid multilevel inverter with reduced harmonic using hybrid modulation technique

Abstract: <span>This paper studies the Asymmetric cascaded three phase multilevel inverter developed with hybrid modulation technique applied for an industrial application. The aim of this paper to reduce the Total harmonics distortion in the cascaded multi level inverter by introducing the new concept to develop the three phase CMLI. This inverter has two segments, one segment has H-bridge inverter and another segment has sequential arrangement of power semi conductor switches with asymmetrical voltage so… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…A three-stage inverter changes over a DC contribution to a three-stage AC. Its three arms are regularly deferred by an edge of 120° to create a three-stage AC supply [26]. Exchanging of inverter switches happens after each T/6 of time T (60° point interim).…”
Section: 22three Phase Invertermentioning
confidence: 99%
“…A three-stage inverter changes over a DC contribution to a three-stage AC. Its three arms are regularly deferred by an edge of 120° to create a three-stage AC supply [26]. Exchanging of inverter switches happens after each T/6 of time T (60° point interim).…”
Section: 22three Phase Invertermentioning
confidence: 99%
“…Switching control of cascaded compact modular MLI is implemented using pulse with modulation in [21]. Hybrid asymmetrical topology is proposed in [22], in this work THD is reduces using improved modulation technique. Various other methods of high frequency PWM techniques were used to improve the THD and quality of the inverter [23].…”
Section: Modulation Strategymentioning
confidence: 99%
“…Cascaded H-Bridge MLI Topology conditional simultaneous DC resource subsist of Single DC supply and Multiple DC supply [11]. In Single DC supply, the Cascaded H-Bridge MLI persist associated in parallel as a consequence, through the production containing separate CHB, the subsided frequency transformer is coupled [12]. Through expanding the 'n' statistic of levels, the Transformer is diluted, being various H-bridge inverters [13].…”
Section: Introductionmentioning
confidence: 99%