2011
DOI: 10.1109/tns.2011.2158111
|View full text |Cite
|
Sign up to set email alerts
|

ATCA-Based Hardware for Control and Data Acquisition on Nuclear Fusion Fast Control Plant Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2012
2012
2016
2016

Publication Types

Select...
6
1

Relationship

5
2

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 5 publications
0
11
0
Order By: Relevance
“…As so, the remote update method was also tested in the Advanced Mezzanine Card (AMC-MKX1) prototype module [12], installed on the ATCA-PTSW-AMC4 carrier module from ITER Fast Plant System Controller catalogue [13], [14]. The AMC-MKX1 module was specially conceived for real-time spectroscopy applications expecting to deliver and process data at a rate of up to 100 GB/s.…”
Section: Resultsmentioning
confidence: 99%
“…As so, the remote update method was also tested in the Advanced Mezzanine Card (AMC-MKX1) prototype module [12], installed on the ATCA-PTSW-AMC4 carrier module from ITER Fast Plant System Controller catalogue [13], [14]. The AMC-MKX1 module was specially conceived for real-time spectroscopy applications expecting to deliver and process data at a rate of up to 100 GB/s.…”
Section: Resultsmentioning
confidence: 99%
“…Moreover, it can be considered a safety solution once the initial FPGA code is never deleted during the update process. FPGA is preferably [9] installed on the ATCA-PTSW-AMC4 carrier module from ITER Fast Plant System Controller catalogue [5], [10]. The ATCA-PTSW-AMC4 is connected to a RTM module with PCIe external cable interface for connection to the host PC.…”
Section: Discussionmentioning
confidence: 99%
“…The shelf backplane provides several network topologies with possible redundancy schemes to be configured on the specified ATCA interfaces [6]. Logical slot numbers 1 and 2 are hub-dedicated slots, while the remaining (3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14) are node slots.…”
Section: Canddaq Overviewmentioning
confidence: 99%
“…The current application uses digitizing units ATCA-IO-PROCESSOR [7] on slots 3 and 5 and a PCI express (PCIe) and timing switch ATCA-PTSW-AMC4 [8] which handles the digitizers' data and timing signals. These in-house developed hardware components belong to the "ITER Catalogue of I&C Products" [9].…”
Section: Canddaq Overviewmentioning
confidence: 99%