Atmospheric Pressure Electrospray Ionization Mass Spectra of Glucose and 2-Fluorodeoxyglucose for Quantitative Analysis of 2-Fluorodeoxyglucose by High-Performance Liquid Chromatography

Abstract: 2-Fluoro-2-deoxy-D-glucose (FDG) labeled by fluorine-18 is the most widely used radiopharmaceutical for positron emission tomography (PET). For high-performance liquid chromatography (HPLC)/MS assay and quality control, the mass spectra of FDG and glucose (Glc) in organic + water solutions were studied by flow injection analysis (FIA) and in a chromatographic eluate. In acetonitrile (MeCN) + 0.025% ammonium formate (NH(4)HCO(2)) solvent (80 : 20), electrospray ionisation (ESI) of glucose-FDG provides M.NH(4)(+… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2003
2003
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 20 publications
1
3
0
Order By: Relevance
“…The UPLC-ESI-MS analyses of the sugar components of both the samples confirmed glucose as the sole monomer present, and no other sugars were detected, confirming SL-YS3 to be an SL type of biosurfactant. The mass spectral analyses substantiated the same upon comparison with previous literature (Macášek et al, 2003;Pathak et al, 2015).…”
Section: Discussionsupporting
confidence: 81%
“…The UPLC-ESI-MS analyses of the sugar components of both the samples confirmed glucose as the sole monomer present, and no other sugars were detected, confirming SL-YS3 to be an SL type of biosurfactant. The mass spectral analyses substantiated the same upon comparison with previous literature (Macášek et al, 2003;Pathak et al, 2015).…”
Section: Discussionsupporting
confidence: 81%
“…The lack of acidic sites in neutral oligosaccharides reducing the ability of forming the deprotonated molecules ([M − H] - ) is probably the reason for the small number of the papers dealing with the negative-ion MALDI Time of Flight (TOF) MS analyses of neutral oligosaccharides ( , ). Alternative ways to charge the neutral oligosaccharides are either attachment of a small inorganic anion A - to form the anionic adduct [M + A] - ( , ) or covalent binding of negatively charged labels ( ). There is no general anion dopant for oligosaccharide analysis by MALDI-TOF MS; by now, mainly hydrogen sulfate and chloride are used ( , ).…”
Section: Introductionmentioning
confidence: 99%
“…Various methods have been described to determine the quantity of PET molecules in pharmaceutical fl uids: HPLC with UV absorbance, electrochemical (Alexoff et al, 1992;Nakao et al, 2006), mass spectrometry (MS) (Hyllbrant et al, 1999;Macasek et al, 2003) and scintillation proximity assay (Beauregard et al, 2007). Among these methods, LC/MS is perhaps the most sensitive and can give reliable results; however, it requires quite expensive equipment and a higher operating cost, and is therefore not suitable for routine analysis in PET facilities.…”
Section: Introductionmentioning
confidence: 99%