Atrial Defibrillation Thresholds of Electrode Configurations Available to an Atrioventricular Defibrillator

Abstract: The atrial defibrillation threshold of CS-->SVC+Can is significantly lower than that of RV-->SVC+Can. In addition, the low atrial defibrillation threshold of RV+CS-->SVC+Can merits further investigation. Based on corroboration of low atrial defibrillation thresholds of CS-based configurations in humans, physicians might consider using CS leads with atrioventricular defibrillators.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2003
2003
2010
2010

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…The study shows that the addition of a shocking electrode within the CS may allow conversion of atrial tachyarrhythmia/AF with low energies. The net advantage of this lead configuration has been demonstrated in animal studies, 8 though human data are limited 9 . Insertion of the CS lead did not prolong the ICD implant procedure.…”
Section: Discussionmentioning
confidence: 96%
“…The study shows that the addition of a shocking electrode within the CS may allow conversion of atrial tachyarrhythmia/AF with low energies. The net advantage of this lead configuration has been demonstrated in animal studies, 8 though human data are limited 9 . Insertion of the CS lead did not prolong the ICD implant procedure.…”
Section: Discussionmentioning
confidence: 96%
“…In 6 of the Control animals, methylcholine at 1 g/250 ml saline IV11 was infused until a 20-mmHg decrease in the blood pressure and a 20% decrease in heart rate or spontaneous AF was observed. Once the blood pressure stabilized, the mapping protocol was performed.…”
Section: Methodsmentioning
confidence: 99%
“…Atrial defibrillation efficacy is influenced by many factors, such as the shocking lead configuration and the defibrillation waveform 13,14 , 17,18 . In animal studies, defibrillation efficacy was maximized with biphasic waveforms and lead configurations that incorporated a CS electrode 19 . Because the CS is positioned posteriorly near the left atrium, it makes intuitive sense that a CS electrode would lower atrial DFTs.…”
Section: Discussionmentioning
confidence: 99%