Attenuation-Correction Induced Artifact in F-18 FDG PET Imaging Following Total Knee Replacement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

2
18
0

Year Published

2004
2004
2014
2014

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(20 citation statements)
references
References 9 publications
2
18
0
Order By: Relevance
“…The presence of artifacts on attenuation-corrected images has also been observed in knee prostheses; in a phantom study, Van Acker et al [28] showed that artifacts mimicking FDG uptake adjacent to a knee prosthesis can arise in attenuation-corrected images obtained with different methods of image reconstruction. In addition, Heiba et al [35] reported the observation of an artifact within the joint space of total knee metallic prostheses in two patients on attenuationcorrected images. No uptake, however, was noted in the same location on the nonattenuation-corrected images [35].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The presence of artifacts on attenuation-corrected images has also been observed in knee prostheses; in a phantom study, Van Acker et al [28] showed that artifacts mimicking FDG uptake adjacent to a knee prosthesis can arise in attenuation-corrected images obtained with different methods of image reconstruction. In addition, Heiba et al [35] reported the observation of an artifact within the joint space of total knee metallic prostheses in two patients on attenuationcorrected images. No uptake, however, was noted in the same location on the nonattenuation-corrected images [35].…”
Section: Discussionmentioning
confidence: 99%
“…In addition, Heiba et al [35] reported the observation of an artifact within the joint space of total knee metallic prostheses in two patients on attenuationcorrected images. No uptake, however, was noted in the same location on the nonattenuation-corrected images [35]. Thus, verification of attenuation-corrected images against nonattenuation-corrected images may avoid false-positive results because of the abovementioned reasons.…”
Section: Discussionmentioning
confidence: 99%
“…For patients with metallic implants, 18 F-FDG PET has an advantage over other imaging modalities since FDG uptake is not hampered by metallic artifacts [12]. However, 18 F-FDG PET/ CT has several limitations for detecting local recurrence in patients treated with endoprosthetic replacement due to the increased FDG uptake around the prosthesis, irrespective of local recurrence [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, their clinical significance in oncological imaging has not been studied thoroughly compared with other metallic objects such as dental metallic implants [6,15,16] and orthopedic prostheses [12,17]. Some studies reported that pacemakers might induce falsely increased uptake at the site of the implant [18,19] which can be misinterpreted as a metabolically active tumour or metastatic deposit.…”
Section: Introductionmentioning
confidence: 99%