2008
DOI: 10.1016/j.optlaseng.2007.08.006
|View full text |Cite
|
Sign up to set email alerts
|

Automated interferometric technique for express analysis of the refractive indices in isotropic and anisotropic optical materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(6 citation statements)
references
References 10 publications
0
6
0
Order By: Relevance
“…The optical pathlength, Δ k , induced by the applied stress, m , can be compensated by rotating the quartz plate by angle ( Δ k = Δ( )) in a way to keep the output light intensity at the same level. Following the route given in [38] it is easily to show that the angular changes of the optical pathlength are defined as Δ( ) = [ 1 − cos − + ( 2 − si n 2 ) 1∕2 ] ,…”
Section: Methodsmentioning
confidence: 99%
“…The optical pathlength, Δ k , induced by the applied stress, m , can be compensated by rotating the quartz plate by angle ( Δ k = Δ( )) in a way to keep the output light intensity at the same level. Following the route given in [38] it is easily to show that the angular changes of the optical pathlength are defined as Δ( ) = [ 1 − cos − + ( 2 − si n 2 ) 1∕2 ] ,…”
Section: Methodsmentioning
confidence: 99%
“…For the details regarding the derivation of Eq. (2), we refer readers to the recent publications [13, 14]. The difference in the optical path lengths δΔ = Δ(φ) – Δ(0) may be determined from the interference pattern shift, whereas the sample is turned out from its ZP on the angle φ.…”
Section: Laboratory Setupmentioning
confidence: 99%
“…In biological sciences, refractometry was employed to determine salinity levels due to total plasma protein (TPP) in fish blood samples 1 and in avian species, 2 to study the molecular basis of virus entry by analyzing the interactions between cellular receptors of herpes virus and the viral glycoproteins in a molecular level, 3 to evaluate the purity and the quality of antimalarial drugs, 4 to rapidly measure glucose concentration in blood, 5,6 and to diagnose and evaluate the evolution of tumors in breast tissues. 7 By performing refractive index measurements, the study of bubble flow, 8 as well as the characterization of optical, 9 polymeric, 10,11 and chemical 12,13 materials can be carried out. For such a large variety of applications many refractometry devices were proposed and developed concerning the particularities of each application.…”
Section: Introductionmentioning
confidence: 99%