2022
DOI: 10.3389/feart.2022.794266
|View full text |Cite
|
Sign up to set email alerts
|

Automated mineralogy (SEM-EDS) approach to sandstone reservoir quality and diagenesis

Abstract: Porosity and permeability define the reservoir quality of a sandstone. Porosity and permeability are controlled by primary sedimentary characteristics and subsequent diagenetic modification. Grain size, sorting, detrital mineralogy, and matrix content are defined at the point of deposition. Bioturbation, infiltration, continued alteration of reactive minerals and soft sediment deformation can occur soon after deposition and, together with the primary characteristics, these condition, or define, how a sediment … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(1 citation statement)
references
References 84 publications
0
1
0
Order By: Relevance
“…The SEM‐EDS instrument used in this study was an FEI WellSite QEMSCAN, at the University of Liverpool, using a tungsten‐filament, operating at 15 kV and equipped with two Bruker EDS detectors (Wooldridge et al, 2018). The technique makes use of a Scanning Electron Microscope (SEM) equipped with two or more high‐speed Energy Dispersive X‐Ray Spectroscopy (EDS) detectors (Armitage et al, 2011; Barshep & Worden, 2021; Worden & Utley, 2022; Worden, Utley et al, 2018) to give a quantitative proportion of mineral assemblages. In this study, the ideal minimum practical spacing resolution of 2 μm was used for higher resolution analyses and 20 μm spacing was used where average mineralogy across a whole polished section was required.…”
Section: Methodsmentioning
confidence: 99%
“…The SEM‐EDS instrument used in this study was an FEI WellSite QEMSCAN, at the University of Liverpool, using a tungsten‐filament, operating at 15 kV and equipped with two Bruker EDS detectors (Wooldridge et al, 2018). The technique makes use of a Scanning Electron Microscope (SEM) equipped with two or more high‐speed Energy Dispersive X‐Ray Spectroscopy (EDS) detectors (Armitage et al, 2011; Barshep & Worden, 2021; Worden & Utley, 2022; Worden, Utley et al, 2018) to give a quantitative proportion of mineral assemblages. In this study, the ideal minimum practical spacing resolution of 2 μm was used for higher resolution analyses and 20 μm spacing was used where average mineralogy across a whole polished section was required.…”
Section: Methodsmentioning
confidence: 99%