Automated preconcentration of Fe, Zn, Cu, Ni, Cd, Pb, Co, and Mn in seawater with analysis using high-resolution sector field inductively-coupled plasma mass spectrometry

Abstract: A rapid, automated, high-throughput analytical method capable of simultaneous analysis of multiple elements at trace and ultratrace levels is required to investigate the biogeochemical cycle of trace metals in the ocean. Here we present an analytical approach which uses a commercially available automated preconcentration device (SeaFAST) with accurate volume loading and in-line pH buffering of the sample prior to loading onto a chelating resin (WAKO) and subsequent simultaneous analysis of iron (Fe), zinc (Zn)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
112
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 155 publications
(114 citation statements)
references
References 37 publications
2
112
0
Order By: Relevance
“…Seawater samples for dissolved trace element analysis were collected in acid‐washed 125‐mL low‐density polyethylene sample bottles (Nalgene), filtered inline using a 0.8/0.2‐μm AcroPak1000 ™ (Pall) filter capsule. Samples were acidified with ultrapure hydrochloric acid (UpA grade, Romil) to pH 1.9 for >6 months, subject to 4‐hr UV irradiation in 30‐mL fluorinated ethylene propylene bottles, preconcentrated on a modified Sea FAST system (Elemental Scientific Inc), and then analyzed using an Element XR inductively coupled plasma‐mass spectrometer (Thermo Finnigan; Rapp et al, ). Isotope dilution and standard additions were used to quantify Fe and Co, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Seawater samples for dissolved trace element analysis were collected in acid‐washed 125‐mL low‐density polyethylene sample bottles (Nalgene), filtered inline using a 0.8/0.2‐μm AcroPak1000 ™ (Pall) filter capsule. Samples were acidified with ultrapure hydrochloric acid (UpA grade, Romil) to pH 1.9 for >6 months, subject to 4‐hr UV irradiation in 30‐mL fluorinated ethylene propylene bottles, preconcentrated on a modified Sea FAST system (Elemental Scientific Inc), and then analyzed using an Element XR inductively coupled plasma‐mass spectrometer (Thermo Finnigan; Rapp et al, ). Isotope dilution and standard additions were used to quantify Fe and Co, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…Concentrations of dissolved and total dissolvable Fe, Mn, and Al in seawater were determined by offline pre-concentration and isotope dilution/standard addition ICP-MS (Thermo Fisher Scientific Element2 XR) according to Rapp et al (2017). For a more detailed description of the method and measured reference materials see Sect.…”
Section: Trace Metal Analysis Of Seawatermentioning
confidence: 99%
“…One line of reasoning is that the Borohydride method produces lower recoveries due to trace metal analytes coprecipitation sensitivities to pH, while Online preconcentration allows for a much wider range (Biller and Bruland 2012). Another factor to consider for Online accuracy is loading rate and volume of the preconcentration column; Rapp et al (2017), for example, obtained significantly low recoveries for Ni using a resin volume of 15 μL in contrast to the 200 μL column in the current study. Sample replicates for each study recovered all analytes within 9% as relative percent difference (RPD).…”
Section: Blanks and Accuracymentioning
confidence: 77%