2022
DOI: 10.1002/jlcr.3974
|View full text |Cite
|
Sign up to set email alerts
|

Automated radiochemical synthesis of pharmaceutical grade [18F]FLT using 3‐N‐Boc‐5′‐O‐dimethoxytrityl‐3′‐O‐nosyl‐thymidine precursor and its Sep‐Pak® purification employing selective elution from reversed phase

Abstract: Pharmaceutical grade 3 0 -deoxy-3 0 -[ 18 F]fluorothymidine [ 18 F]FLT was synthesized using 3-N-Boc-5 0 -O-dimethoxytrityl-3 0 -O-nosyl-thymidine (BOC-Nosyl) precursor, in the general purpose TRACERlab FX modules. Purification of [ 18 F]FLT, via solid phase extraction (SPE) after radiosynthesis, using a combination of different SPE cartridges, yielded satisfactory results, with radiochemical and chemical purity >99%. While the non-decay corrected radiochemical yield (RCY) with 20 mg (24 μmole) of BOC-Nosyl pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 25 publications
1
2
0
Order By: Relevance
“…We also observed radioactivity loss in a gaseous form, which was marked as “uncontrolled losses” (entry 9, Table 2 ). Comparable or slightly lower RCY (10%, corrected for decay) for the [ 18 F]FLT has been recently reported [ 22 ] using a similar GE TRACERlab FX automated platform ( Table 1 , entry 5). The authors used 20 mg of I and employed a quite complex purification procedure based on four different types of SPE cartridges.…”
Section: Resultssupporting
confidence: 69%
See 2 more Smart Citations
“…We also observed radioactivity loss in a gaseous form, which was marked as “uncontrolled losses” (entry 9, Table 2 ). Comparable or slightly lower RCY (10%, corrected for decay) for the [ 18 F]FLT has been recently reported [ 22 ] using a similar GE TRACERlab FX automated platform ( Table 1 , entry 5). The authors used 20 mg of I and employed a quite complex purification procedure based on four different types of SPE cartridges.…”
Section: Resultssupporting
confidence: 69%
“…As an alternative to HPLC purification, the development of solid-phase extraction (SPE) techniques based on commercially available disposable cartridges has been the focus of radiopharmaceutical research for many radiotracers including [ 18 F]FLT [ 16 , 20 , 21 , 22 ]. The SPE method, in principle, is very simple, fast, reliable, and is easily adaptable to most automated equipment.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation