Automated Screening and Filtering Scripts for GC×GC-TOFMS Metabolomics Data

Abstract: Comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) is a powerful tool for the analysis of complex mixtures, and it is ideally suited to discovery studies where the entire sample is potentially of interest. Unfortunately, when unit mass resolution mass spectrometers are used, many detected compounds have spectra that do not match well with libraries. This could be due to the compound not being in the library, or the compound having a weak/nonexistent molecular ion cluster. While high-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…Therefore, the qualitative data from the library coupled with retention indices need to be carefully analysed or ideally confirmed with standards to confirm metabolite identification. In contrast, many techniques such as the GC-TOFMS, GC × GC and MS/MS techniques were limited in the past when compared to quadrupole GC-MS by the mass spectral libraries that were available although recent software developments [ 81 ] have enabled improvements [ 82 ]. As an example, it was possible to detect 1000 s of chromatographic peaks when analysing breath samples by GC × GC-TOFMS [ 83 ], but naming even a fraction of these proved difficult.…”
Section: Discussionmentioning
confidence: 99%
“…Therefore, the qualitative data from the library coupled with retention indices need to be carefully analysed or ideally confirmed with standards to confirm metabolite identification. In contrast, many techniques such as the GC-TOFMS, GC × GC and MS/MS techniques were limited in the past when compared to quadrupole GC-MS by the mass spectral libraries that were available although recent software developments [ 81 ] have enabled improvements [ 82 ]. As an example, it was possible to detect 1000 s of chromatographic peaks when analysing breath samples by GC × GC-TOFMS [ 83 ], but naming even a fraction of these proved difficult.…”
Section: Discussionmentioning
confidence: 99%
“…In the case of food-omics or metabolomics applications, dealing with several hundreds or thousands of compounds, an automated screening and filtering script for compound identification may be used. 48 In this study, the approach is based on assessment of MS data (no retention time data needed) with the following steps: (1) calculation of expected molecular ions of the compound family (e.g., saturated or unsaturated FAME) based on its structure; (2) neutral loss may be subtracted from the calculated molecular ion; (3) evaluation of other prominent features such as mass fragment intensity. For example, in the case of saturated FAME analysis, (1) confirmation that the molecule is a FAME.…”
Section: ■ Strategies In Food Analysismentioning
confidence: 99%
“…The resulting chromatograms were processed with automated filtering scripts and displayed as a contour map [47]. The color scale on the map indicated the intensity or concentration of the peaks, with red denoting high intensity and dark blue representing the baseline or background (refer to part 2 in Supplementary Materials).…”
Section: Data Processing and Analysismentioning