2011
DOI: 10.1007/s11837-011-0041-2
|View full text |Cite
|
Sign up to set email alerts
|

Automated serial sectioning methods for rapid collection of 3-D microstructure data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
25
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(25 citation statements)
references
References 32 publications
(24 reference statements)
0
25
0
Order By: Relevance
“…Indeed, material was not lost during the welding process. In an attempt to validate the cross‐sectional area measurements, analysis was performed on a three‐dimensional image that was constructed from two‐dimensional slices that were collected using an automated serial sectioning process . Phase volumes were determined by summing the area fractions of specific phases for each slice of the reconstructed three‐dimensional image.…”
Section: Resultsmentioning
confidence: 99%
“…Indeed, material was not lost during the welding process. In an attempt to validate the cross‐sectional area measurements, analysis was performed on a three‐dimensional image that was constructed from two‐dimensional slices that were collected using an automated serial sectioning process . Phase volumes were determined by summing the area fractions of specific phases for each slice of the reconstructed three‐dimensional image.…”
Section: Resultsmentioning
confidence: 99%
“…Although serial sectioning, x-ray tomography, atom probe tomography, and other data collection techniques have been employed for some years, 1-8 new collection methods are being introduced that are either partially or fully automated. 9,10 Automated data collection techniques, particularly those that can incorporate crystallographic measurements, remove the initial barrier to 3D materials analysis-the perception that unsupportable investments of time and resources are required for data collection. (Although data collection certainly requires significant investment of time and resources, many have noted that far more time and resources are expended on the processing and analysis of the data.…”
Section: Data Collectionmentioning
confidence: 99%
“…Although extremely time consuming this method has the advantage over tomography techniques (see next paragraph) of being able to picture particles in a medium showing a poor contrast. It can also be associated to a series of microanalytical instruments to offer 3D imaging coupled to EDX and EBSD information for example (Uchic et al, 2011).…”
Section: Automated Serial Sectioning Tomographymentioning
confidence: 99%