2014
DOI: 10.1016/j.cmpb.2014.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Automatic detection of the carotid lumen axis in B-mode ultrasound images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2014
2014
2016
2016

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(17 citation statements)
references
References 12 publications
0
17
0
Order By: Relevance
“…The method proposed in [79] was also later applied in [80] for the automated detection of the lumen in CCA B-mode images using a Gaussian smoothed filter and then a dynamic programming scheme, which extracts the dominant paths of local minima of the intensity and the dominant paths of local maxima of the gradient magnitude with the gradient pointing downwards. Similar results were reported in [79], but with a greater accuracy (99.5 %).…”
Section: Atherosclerotic Carotid Plaque Image Segmentation Techniquesmentioning
confidence: 99%
“…The method proposed in [79] was also later applied in [80] for the automated detection of the lumen in CCA B-mode images using a Gaussian smoothed filter and then a dynamic programming scheme, which extracts the dominant paths of local minima of the intensity and the dominant paths of local maxima of the gradient magnitude with the gradient pointing downwards. Similar results were reported in [79], but with a greater accuracy (99.5 %).…”
Section: Atherosclerotic Carotid Plaque Image Segmentation Techniquesmentioning
confidence: 99%
“…However, we have found that some authors pointed out the need for automated measurement of carotid lumen diameter [47][48][49]. The lumen segmentation algorithms have been classified into regional-based vs. boundary-based: region-based [17,18], boundary-based [19][20][21][22]. Here, we describe each of these techniques and their limitations and discuss how they validated the measured parameters.…”
Section: Brief Survey and Benchmarkingmentioning
confidence: 99%
“…Lumen axis detection for carotid artery was discussed by Rocha et al [22] using dynamic programming. They assumed that the CCA is the largest blood vessel nearest to the bottom of the image and the jugular vein will appear above the CCA.…”
Section: Brief Survey and Benchmarkingmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the method might result in false CCA detections due to confusion with other structures of similar shape. In a recent paper, Rocha et al [ 19 ] presented an independently-developed approach to CCA detection that proposes a solution for the detection of multiple candidates.…”
Section: Introductionmentioning
confidence: 99%