2016
DOI: 10.1016/j.geoderma.2015.08.022
|View full text |Cite
|
Sign up to set email alerts
|

Automating double ring infiltrometer with an Arduino microcontroller

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
17
0
5

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 39 publications
(23 citation statements)
references
References 15 publications
1
17
0
5
Order By: Relevance
“…The ALog is part of a community of open-source tools for scientific research (Harnett, 2011;Pearce, 2012;Cressey, 2017) that includes both sensors (Keeler and Brugger, 2012;Barnard et al, 2014;Fatehnia et al, 2016;Hut et al, 2016) and automated data loggers (Fisher, 2012;Hund et al, 2016;Beddows and Mallon, 2018). Of these, the ALog BottleLogger designs have the lowest power consumption (Table 1).…”
Section: Discussionmentioning
confidence: 99%
“…The ALog is part of a community of open-source tools for scientific research (Harnett, 2011;Pearce, 2012;Cressey, 2017) that includes both sensors (Keeler and Brugger, 2012;Barnard et al, 2014;Fatehnia et al, 2016;Hut et al, 2016) and automated data loggers (Fisher, 2012;Hund et al, 2016;Beddows and Mallon, 2018). Of these, the ALog BottleLogger designs have the lowest power consumption (Table 1).…”
Section: Discussionmentioning
confidence: 99%
“…AI techniques can be used in solving engineering problems [4][5][6][7][8][9][10][11] even if the underlying relationships are unknown or the physical meaning is difficult to explain. This is one of the main advantages of these techniques when compared to most physically-based empirical and statistical methods.…”
Section: Overview Of Artificial Intelligencementioning
confidence: 99%
“…Single ring (SRI) or double ring (DRI) infiltrometers are one of the most used devices for in-situ determination of infiltration rates and saturated hydraulic conductivity. Several studies have used infiltrometers [10][11][12][13][14]; recently, Nestingen et al [15] made a comparison between three types of infiltrometers (modified Philip-Dunne, double-ring, and minidisk infiltrometers) and they found that the double ring infiltrometer was the most precise. With the recent advances in microelectronics, telecommunications and software, some developments have been done to automate this device [13,16,17], which has been useful to reduce time consumption and increase accuracy.…”
Section: Introductionmentioning
confidence: 99%