2006
DOI: 10.1590/s1415-54192006000200007
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação de um programa de traçado cefalométrico

Abstract: OBJETIVO: avaliar o programa de traçado cefalométrico Radiocef 2.0 quanto à confiabilidade e precisão, comparativamente ao método manual e ao programa Dentofacial Planner 7.02 (Gold Standard). METODOLOGIA: a amostra constou de 50 telerradiografias laterais de boa qualidade, de pacientes de ambos os gêneros, na faixa etária dos 11 aos 24 anos, pertencentes aos arquivos da disciplina de Ortodontia da Faculdade de Odontologia de Bauru, da Universidade de São Paulo. A partir das diferentes formas de medições execu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
12
0
4

Year Published

2009
2009
2017
2017

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(19 citation statements)
references
References 47 publications
3
12
0
4
Order By: Relevance
“…Erkan et al 8 compared Dolphin ® , Vistadent ® , Nemoceph ® and Ceph Quick ® software, and did not find statistically significant difference among them. In the study of Vasconcelos et al 6 , Radiocef ® was compared to Dental Planner ® , but also no statistically significant difference was found. Furthermore, Glaros et al [9][10] compared Dolphin Imaging ® and Vistadent ® software.…”
Section: Discussionmentioning
confidence: 92%
See 4 more Smart Citations
“…Erkan et al 8 compared Dolphin ® , Vistadent ® , Nemoceph ® and Ceph Quick ® software, and did not find statistically significant difference among them. In the study of Vasconcelos et al 6 , Radiocef ® was compared to Dental Planner ® , but also no statistically significant difference was found. Furthermore, Glaros et al [9][10] compared Dolphin Imaging ® and Vistadent ® software.…”
Section: Discussionmentioning
confidence: 92%
“…The authors observed that points in the incisor teeth region are difficult to locate, in addition to the magnitudes related to them having low reliability. For Vasconcelos et al 6 , the main deterrent noticed in locating incisive dental apex points occurs because the digital image produces gray shades that blend into each other in this region. According to Jabbal et al 13 , orthodontic treatment can anteriorly or posteriorly force the lower incisors both in body and in a tipping motion, and this is monitored by comparing lower incisor angulation to the mandibular border using consecutive lateral cephalometric radiographs.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations