2021
DOI: 10.1016/j.engstruct.2021.112452
|View full text |Cite
|
Sign up to set email alerts
|

Axial compressive behaviour and design calculations on recycled aggregate concrete-filled steel tubular (RAC-FST) stub columns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
1
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 54 publications
(10 citation statements)
references
References 36 publications
0
1
0
Order By: Relevance
“…Pacheco et al suggest that the conversion coefficient of 150 mm cubic to cylinder with a diameter of 150 mm for recycled concrete is 0.77 [56]. Additionally, the conversion coefficient of 150 mm cubic to prism with dimensions of 150 mm × 150 mm × 300 mm for recycled concrete is 0.67 [57,58].…”
Section: Theory Calculation Formulas For Ultimate Capacity Of Design ...mentioning
confidence: 99%
“…Pacheco et al suggest that the conversion coefficient of 150 mm cubic to cylinder with a diameter of 150 mm for recycled concrete is 0.77 [56]. Additionally, the conversion coefficient of 150 mm cubic to prism with dimensions of 150 mm × 150 mm × 300 mm for recycled concrete is 0.67 [57,58].…”
Section: Theory Calculation Formulas For Ultimate Capacity Of Design ...mentioning
confidence: 99%
“…The composite structures of steel tubular and concrete can significantly improve the stiffness of members and meet the functional requirement of deformation and stiffness when the structures are in normal use. In addition, the members formed by combining steel tubular with recycled concrete can not only make up for the shortage of recycled concrete, but also reduce the environmental damage caused by natural aggregate mining and partially solve the problems of environmental pollution and land occupation caused by construction waste landfill [4][5][6]. The combination of high-strength steel (HSS) tubular and HSC can reach the strength potential of HSS and ultra-high-performance concrete (UHPC), reduce the weight of civil engineering structures, and provide remarkable social and economic benefits [7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…The ductility of UHSSCCFST columns was usually lower than that of ordinary- As the most basic structural member, the axial compression behavior of CFST columns has been widely studied. Lyu et al [5] carried out axial compression research on 32 recycled CFST (RCFST) short columns, considering the replacement ratio of recycled coarse aggregate (RCA). RCA can affect the ultimate strength and elastic modulus.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The results showed that the source and the replacement ratio of recycled aggregates slightly affect the static responses and collapse process of the RACFST specimens. An experimental study that contains 32 RACFST specimens was reported by Lyu [ 25 ]. The confinement factor and the material strength were found to be the most influential to the bearing capacity of the columns, while the replacement ratio of coarse aggregate considerably affects the strength index of the RAC.…”
Section: Introductionmentioning
confidence: 99%