2010
DOI: 10.1152/ajpheart.00924.2009
|View full text |Cite
|
Sign up to set email alerts
|

Baroreflex control of muscle sympathetic nerve activity: a nonpharmacological measure of baroreflex sensitivity

Abstract: Hart EC, Joyner MJ, Wallin BG, Karlsson T, Curry TB, Charkoudian N. Baroreflex control of muscle sympathetic nerve activity: a nonpharmacological measure of baroreflex sensitivity. Am J Physiol Heart Circ Physiol 298: H816 -H822, 2010. First published December 11, 2009; doi:10.1152/ajpheart.00924.2009.-The sensitivity of baroreflex control of sympathetic nerve activity (SNA) represents the responsiveness of SNA to changes in blood pressure. In a slightly different analysis, the baroreflex threshold measures th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
101
1
2

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 87 publications
(108 citation statements)
references
References 30 publications
4
101
1
2
Order By: Relevance
“…This plot further reveals a close relationship between measures of PET CO 2 and Pa CO 2 , as demonstrated by a small measurement bias of Ϫ0.4 mmHg. A proportional bias exists if the slope of the relationship between the difference of two measurements and the mean of the two measurements is significantly different from zero [i.e., the difference between the two methods changes as the average values from the two methods becomes smaller or larger (6,14,16)]. In the current study, a proportional bias was not detected (r ϭ 0.01, P ϭ 0.94, slope Ϫ0.004).…”
Section: Considerations/limitationscontrasting
confidence: 55%
See 1 more Smart Citation
“…This plot further reveals a close relationship between measures of PET CO 2 and Pa CO 2 , as demonstrated by a small measurement bias of Ϫ0.4 mmHg. A proportional bias exists if the slope of the relationship between the difference of two measurements and the mean of the two measurements is significantly different from zero [i.e., the difference between the two methods changes as the average values from the two methods becomes smaller or larger (6,14,16)]. In the current study, a proportional bias was not detected (r ϭ 0.01, P ϭ 0.94, slope Ϫ0.004).…”
Section: Considerations/limitationscontrasting
confidence: 55%
“…Comparisons between Pa CO 2 and PETCO 2 measures, during the three thermal conditions, were also evaluated using the methods of differences as described by Bland-Altman (2). The Bland-Altman plot was subsequently analyzed by linear regression analysis to determine if the slope of the relationship was greater than zero, which would indicate that a proportional bias was present [i.e., difference between two methods changes as the average values from the two methods becomes smaller or larger (6,14,16)]. Furthermore, a fixed bias is present if the 95% confidence limit of the Bland-Altman plot does not include zero (14,16).…”
Section: Aim 1: Petco 2 Vs Paco 2 During Normothermia and Two Levelsmentioning
confidence: 99%
“…This technique is highly correlated with sympathetic baroreflex sensitivity derived using the more invasive modified Oxford approach (i.e., bolus intravenous administration of sodium nitroprusside and phenylephrine) (22). Briefly, the diastolic BP for each cardiac cycle within each analysis region of interest was grouped into 2-mmHg pressure bins.…”
Section: Subjectsmentioning
confidence: 99%
“…Recently, a reliable nonpharmacological methodology has emerged to allow the determination of sympathetic BRS during mental stress. Specifically, the relations between spontaneous fluctuations of diastolic arterial blood pressure (DAP) and MSNA can be analyzed in an approach that provides an accurate slope assessment of sympathetic BRS (5,(11)(12)(13)(14)21).…”
mentioning
confidence: 99%