2015
DOI: 10.1088/0964-1726/24/4/045014
|View full text |Cite
|
Sign up to set email alerts
|

Baseline-free delamination inspection in composite plates by synthesizing non-contact air-coupled Lamb wave scan method and virtual time reversal algorithm

Abstract: In the paper, we combined air-coupled Lamb wave scan method and virtual time reversal (VTR) algorithm and proposed a composite baseline-free delamination inspection technique of composite plates. According to VTR algorithm, time reversal process is virtually performed through signal operations and the hardware manipulation for time reversal is not required. Baseline-free damage inspection can be achieved by comparing the first input actuation signal with the reconstructed final signal obtained by VTR algorithm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
38
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 71 publications
(39 citation statements)
references
References 37 publications
1
38
0
Order By: Relevance
“…According to Figure 7, air-coupled transducers and ultrasonic C-scan testing may be included in ultrasonic testing [121][122][123][124][125][126][127][128][129][130][131][132][133]. Air-coupled transducers (ACTs), when coupling media, cannot be applied is an attractive alternative to excite ultrasonic waves and receive those leaked into the air.…”
Section: Nde Techniquesmentioning
confidence: 99%
See 3 more Smart Citations
“…According to Figure 7, air-coupled transducers and ultrasonic C-scan testing may be included in ultrasonic testing [121][122][123][124][125][126][127][128][129][130][131][132][133]. Air-coupled transducers (ACTs), when coupling media, cannot be applied is an attractive alternative to excite ultrasonic waves and receive those leaked into the air.…”
Section: Nde Techniquesmentioning
confidence: 99%
“…In the immersion testing process, a liquid couplant is employed to establish direct contact between a transducer and the composite specimen. Most of the research effort in the technical literature searched regarding the ultrasonic C-scan testing has been focused on either verification of other NDE techniques with ultrasonic C-scan as a reference standard [35,47,89,91,109,112,126] or yielding supplementary information [26,38,105,117,127].…”
Section: Nde Techniquesmentioning
confidence: 99%
See 2 more Smart Citations
“…That is, the initial input signal and the secondary excitation signal are actuated by the same actuator. Liu et al [17] presented a virtual time reversal algorithm which only needs one actuating-receiving step to obtain the reconstructed signal. Agrahari et al [18] investigated the influences of adhesive layer between the transducer and the host plate, the excitation parameters, the transducer size and the plate thickness on the performance of the TRP to develop an effective damage detection strategy.…”
Section: Introductionmentioning
confidence: 99%