Batch measurements of wood density on intact or prepared drill cores using x-ray microdensitometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
55
0

Year Published

2008
2008
2016
2016

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 77 publications
(55 citation statements)
references
References 0 publications
0
55
0
Order By: Relevance
“…Extractives were not removed. The X-ray microdensitometry (ITRAX) scanning (Bergsten et al, 2001) was done using a step size of 25 μm intervals with the following settings for tube: voltage of 30 kV, current value of 25 mA and an exposure time of 20 ms (Peltola et al, 2007). The first year of the SA chronology occurs in AD 673.…”
Section: Acquiring the Mxd Datamentioning
confidence: 99%
“…Extractives were not removed. The X-ray microdensitometry (ITRAX) scanning (Bergsten et al, 2001) was done using a step size of 25 μm intervals with the following settings for tube: voltage of 30 kV, current value of 25 mA and an exposure time of 20 ms (Peltola et al, 2007). The first year of the SA chronology occurs in AD 673.…”
Section: Acquiring the Mxd Datamentioning
confidence: 99%
“…Wood density was measured by X-ray diffraction using an Itrax Density Scanner (Cox Analytical Systems, http:// www.coxsys.se/itrax_density_scanner.htm). This device is described in more detail in Lindeberg (2001) and Bergsten et al (2001), and in Fries and Ericsson (2006) the procedure followed is described in detail.…”
Section: Progeny Test Plantation Data Collection and Sample Treatmentmentioning
confidence: 99%
“…Thereafter, these wood specimens were kept for a few weeks under fixed environmental conditions before the measurements were carried out, so that they were stabilised to have a moisture content of 12% (air dry). Subsequently, they were scanned with an ITRAX X-ray microdensitometer (Cox Analytical Systems, Göteborg, Sweden), which works with an automatic collimator alignment at a geometrical resolution of 40 measurements per mm (Bergsten et al 2001). In our work, the standard X-ray intensity (30 kV, 35 mA) for X-ray measurements was used.…”
Section: Laboratory Measurementsmentioning
confidence: 99%
“…Afterwards, the X-ray images were analysed with the Density software program (Bergsten et al 2001) and excel macros, and parameters such as ring width (RW, mm), earlywood and latewood widths (EWW and LWW, mm), mean intraring wood density (WD, g/cm 3 ), minimum and maximum wood densities (g/cm 3 ) and earlywood and latewood densities (EWD and LWD, g/cm 3 ) were determined based on intraring density profiles. In this analysis, the mean of the maximum and minimum intraring densities were used as the threshold for earlywood and latewood for each ring; the values above this threshold representing the latewood and the values below the earlywood.…”
Section: Laboratory Measurementsmentioning