“…CONCLUSION We have considered three methods of determining the coordinates of the center of the TC and a device for implementing the methods. At the experimental prototyping stage, a choice was made in favor of a design version of a TCCS with Number of pixels More than 15 × 10 6 (for example, 4872 × 3248) Pixel size, μm 2 At most 10 × 10 Bit count of ADCs, bit 12 (8) Maximum frame rate, frame/sec 3 Sensitivity, lux 0.02 (mono) SNR, dB More than 56 a cubic 3D mark that takes into account the possibility of using it for full-scale adjustment of the laser channels of the installation, with focusing of the radiation of the beams into specified points in the central region of the TC. The TCCS of the developed design makes it possible to match an electronic 3D model of the TC with a system of bodies consisting of the target simulator, the 3D marks, the targets, the final optical modules, etc.…”