2013
DOI: 10.1167/iovs.12-10836
|View full text |Cite
|
Sign up to set email alerts
|

Behavior of Visual Field Index in Advanced Glaucoma

Abstract: The decrease in VFI when MD crosses -20 dB can be highly variable. This has to be considered with the use of VFI in clinical and research settings.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
26
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(27 citation statements)
references
References 19 publications
1
26
0
Order By: Relevance
“…Recent reports suggest that standard structural measures such as RNFL thickness reach a floor effect and visual field tests are highly variable in eyes with advanced glaucoma. 11, 39-42 It is important to evaluate whether OCT-A has a sufficient dynamic range to provide clinically relevant information across the full spectrum of glaucoma severity. In addition, we did not evaluate the possible confounding impact of various systemic conditions, blood pressure and perfusion pressure, glaucoma eye drops, and systemic medications on vessel density and its relationship to standard structural and functional measures.…”
Section: Discussionmentioning
confidence: 99%
“…Recent reports suggest that standard structural measures such as RNFL thickness reach a floor effect and visual field tests are highly variable in eyes with advanced glaucoma. 11, 39-42 It is important to evaluate whether OCT-A has a sufficient dynamic range to provide clinically relevant information across the full spectrum of glaucoma severity. In addition, we did not evaluate the possible confounding impact of various systemic conditions, blood pressure and perfusion pressure, glaucoma eye drops, and systemic medications on vessel density and its relationship to standard structural and functional measures.…”
Section: Discussionmentioning
confidence: 99%
“…Considering the range of VF sensitivity at which a RNFL floor begins, VF tests have been preferred to pRNFLT measurements at the moderate-to-advanced stage of glaucoma for follow-up 12. However, the VF test sometimes shows large fluctuations in patients with advanced glaucoma, rendering it difficult to define actual glaucomatous change 19. By contrast, structural/vascular assessment is not dependent on patient response and may thus yield less variable results if the technology used offers good reproducibility.…”
Section: Discussionmentioning
confidence: 99%
“…This suggests that the VFI is likely insensitive for detecting early visual field loss. Additionally, due to the change in the VFI algorithm, in visual field series in which MD crosses À20 dB, there is a stepwise worsening in VFI and an increase in its variability, reducing the reliability of VFI in these cases (Lee et al, 2014;Rao et al, 2013; Fig. 1).…”
Section: Global Trend Analysismentioning
confidence: 99%